UNDERSTANDING THE LIGHT AND HORN PATTERNS (AC POWER ON)

When the CO Alarm is operating on AC power...

Condition

LED (Red Light)

Horn

POWER UP

LED flashes ON once,
then shines continuously

Horn “chirps” once.

DURING TESTING

LED flashes once every second
during the 10-second test cycle

Horn pattern: 4 beeps,
pause, 4 beeps, pause.

MISSING BATTERY
(DC back-up disabled)

LED shines continuously

Horn is silent.

LOW BATTERY

LED shines continuously

Horn “chirps” once a minute.

ALARM CONDITION
Single CO Alarm
(not interconnected)

LED flashes rapidly,
once every second

Horn pattern: 4 beeps,
pause, 4 beeps, pause,
repeating.

ALARM CONDITION
Interconnected
Series of CO Alarms

LED flashes rapidly on the unit
that triggered the alarm. LEDs
on the other alarms in the series
will not flash.

Horn pattern: 4 beeps,
pause, 4 beeps, pause
repeating, on all CO
alarms.

IN SILENCE MODE

LED flashes rapidly,
once every second

Horn stays quiet for 4 minutes.

“LATCHING” ALARM
INDICATOR

LED flashes
once every 5 seconds

Horn stays quiet.

MALFUNCTION

LED flashes 3 times
synchronized with 3 rapid chirps

Horn sounds 3 rapid chirps
(“chirp-chirp-chirp”) every
minute.