Balanced combusion system – Bock Water heaters Sidewall Vented Oil & Gas Water Heaters User Manual

Page 2

Advertising
background image

www.bockwaterheaters.com

110 South Dickinson Street , Madison, Wisconsin 53703

Toll Free 800.794.2491

Phone 608.257.2225

Fax 608.257.5304

80023 Rev 2/08

*Nipple not included

**Optional setting, consult factory

***Weight includes burner and controls

T&P Valve: Factory Installed

Drain Valve: Factory Installed Brass Valve

Standard Voltage (all): 120V, 60 Hz, 1P

Pressures (all): Working Pressure, 150 psi; Testing Pressure, 300 psi

ASHRAE: All Bock Products Meet or Exceed Current ASHRAE Standards.

Warning: Do not install on combustible flooring. Installation should be in accordance with all national and/or local codes. In the absence of local

codes, refer to NFPA 54, NFPA 31 or ANSI Z.21.10.1.

Caution: The recommended maximum hot water termperature setting for normal residential use is 120°F. Bock recommends a tempering valve or

anti-scald valve be installed and used according to the manufacturer’s directions to prevent scalding.

(on selected models)

Balanced

Combusion

System

Outlet

Outlet

Inlet

T&P

Relief

Valve

D
C

B

E

A

Drain

Valve/

Return

Aquastat

Connection

Outlet

Outlet

Inlet

T&P

Relief

Valve

D

C

B

E

A

Drain

Valve/

Return

Aquastat

Connection

Outlet

Outlet

T&P

Relief

Valve

C

B

E

A

Drain

Valve/

Return

Aquastat

Connection

Inlet

Outlet

Outlet

Inlet

T&P

Relief

Valve

D

C

B

E

A

Drain

Valve/

Return

Aquastat

Connection

Hand-Hole

Inlet

20e-BCS

32E/PG-BCS, 51E/PG-BCS 40E/PG-BCS

120E/PG-BCS, 190E/PG-BCS

Model

Storage

(gal)

Rated Input

Recovery

@ ∆ 90°F

(GPH)

Max. Temp

Setting

(°F)

Inlet

Pipe

Dia.

Outlet

Pipe

Dia.

Return

Pipe

Dia.

Dimensions

Shipping

Weight

(lbs)***

BTH/HR GPH

A

B

C

D

E

Oil

20e-BCS

20

60,000

0.43

66

160

3/4”

3/4”

3/4”

38 1/4”

20”

6”

11”

14 3/4”

210

32E-BCS

32

104,000

0.75

114

160

3/4”

3/4”

3/4”

51”

20”

6”

11”

17”

312

40E-BCS

40

126,000

0.90

136

160

3/4”

3/4”

1”

61”

20”

6”

N/A

18”

344

51E-BCS

50

152,000

1.10

161

160**

1”

1”

3/4”

59”

24”

6”

11”

18”

370

120E-BCS

113

155,000

1.10

163

180

1”

2”**

2”**

67”

31 1/2”

6”

19”

22”

751

190E-BCS

113

190,000

1.35

199

180

1”

2”**

2”**

67”

31 1/2”

6”

19”

22”

751

Gas

32PG-BCS

32

104,000

-

110

160

3/4”

3/4”

3/4”

51”

20”

6”

11”

17”

312

40PG-BCS

40

126,000

-

134

160

3/4”

3/4”

1”

61”

20”

6”

N/A

18”

341

51PG-BCS

50

152,000

-

159

160**

1”

1”

3/4”

59”

24”

6”

11”

18”

370

120PG-BCS

113

155,000

-

160

180

1”

2”**

2”**

67”

31 1/2”

6”

19”

22”

749

190PG-BCS

113

190,000

-

191

180

1”

2”**

2”**

67”

31 1/2”

6”

19”

22”

749

80023.indd 2

5/20/2008 2:24:28 PM

Advertising