BenQ DLP PROJECTOR PE8700 User Manual
Page 31
Advertising

30
3. DVI-Analog Color Alignment Procedure
Default valve(User menu)
contrast color
Sharpness
Video 17
23
3
S-Video 17
23
1
Comp 17
30
0
Comp-HD 17
30
3
RGBHV 17
30
3
DVI-I 17
30
1
The Gamma(RED ,GREEN,BLUE) is
66
for temperature 0,1,2,3,4.
Equipment:
-
Pattern generator (Chroma 2250)
-
Lux meter ( CL-100)
OSD Default value used for DVI-Analog color alignment
Item Value
Item
Value
USER>Picture>
Factory>HDADJ>RG
Brightness 30
R offset
55
Contrast
17 G
offset
63
Color 30
B offset
62
Tint 15
R Gain
89
Sharpness
1 G
Gain
89
Filter 1
B Gain
89
Color Temp
2
Factory>DLP
Brightness
0
Contrast
49
User>Setup>White
Gamma Red, Green,
66
Gamma Red, Green,
0
Advertising