Bryan ab series steam & hot water boilers – Bryan Boilers AB250-S150-FDG User Manual

Page 4

Advertising
background image

Bryan Steam LLC — Leaders Since 1916

783 N. Chili Ave., Peru, Indiana 46970 U.S.A.
Phone:765-473-6651 • Internet:www.bryanboilers.com
Fax: 765-473-3074 • E-mail: [email protected]

Bryan AB Series Steam & Hot Water Boilers

Specifi cations subject to change without notice. Consult factory to consult on other boiler options.

Form No. 7510 ©2005 Bryan Steam LLC

Printed in USA

65-7097

STEAM BOILER DIMENSIONS — inches (cm)

A

B

C

D

E

F

G

H

I

J

K

L

Boiler Length

Width

Height Gas

Train

Supply

Clearance for Min. Tube Floor to

Model

of Outside

Over

Overall

Connection

Nozzle

Return Flue

Flue

Servicing Removal

Flow

Number Jacket Jacket

Jacket

Length

(Approx.)

15 psi

150 psi

Conn. Size Location

Burner Clearance

Nozzle

AB-90

44

15

/

16

38

1

/

2

77

1

/

4

76

1

1

/

4

4 FLG

3 NPT

1

1

/

2

NPT 10

12

36

24

79

5

/

8

(114.1) (97.79) (196.21) (193.0)

(3.2)

(10.16)

(7.62)

(3.81)

(25.4)

(30.5)

(91.4)

(60.9)

(202.24)

AB-120

54

3

/

16

38

1

/

2

77

1

/

4

85

3

/

8

1

1

/

4

4 FLG

3 NPT

1

1

/

2

NPT 10

12

36

24

79

5

/

8

(137.6) (97.79) (196.21) (216.8)

(3.2)

(10.16)

(7.62)

(3.81)

(25.4)

(30.5)

(91.4)

(60.9)

(202.24)

AB-150

63

1

/

2

38

1

/

2

77

1

/

4

94

3

/

4

1

1

/

2

6 FLG

3 NPT

1

1

/

2

NPT 10

12

36

24

79

5

/

8

(161.3) (97.79) (196.21) (260.7)

(3.8)

(15.24)

(7.62)

(3.81)

(25.4)

(30.5)

(91.4)

(60.9)

(202.24)

AB-200

78

15

/

16

38

1

/

2

77

1

/

4

110

2

6 FLG

3 NPT

1

1

/

2

NPT 10

16

1

/

2

36

24

79

5

/

8

(200.5) (97.79) (196.21) (279.4)

(5.1)

(15.24)

(7.62)

(3.81)

(25.4)

(41.9)

(91.4)

(60.9)

(202.24)

AB-250

94

7

/

16

38

1

/

2

77

1

/

4

125

1

/

2

2

6 FLG

3 NPT

1

1

/

2

NPT 12

15

36

24

79

5

/

8

(239.9) (97.79) (196.21) (318.8)

(5.1)

(15.24)

(7.62)

(3.81)

(30.5)

(38.1)

(91.4)

(60.9)

(202.24)

AB-300

108

13

/

16

38

1

/

2

77

1

/

4

140

15

/

16

2

6 FLG

3 NPT

1

1

/

2

NPT 12

15

36

24

79

5

/

8

(276.4) (97.79) (196.21) (358.0)

(5.1)

(15.24)

(7.62)

(3.81)

(30.5)

(38.1)

(91.4)

(60.9)

(202.24)

WATER BOILER DIMENSIONS — inches (cm)

A B C D

E

F

G H I

J

K

L

Boiler Length

Width

Height

Gas

Train

Clearance for

Min. Tube Floor to

Model

of Outside Over

Overall

Connection

Supply Return

Flue Flue

Servicing Removal

Flow

Number Jacket Jacket Jacket

Length

(Approx.)

Nozzle Nozzle

Size

Location

Burner Clearance

Nozzle

AB-90

44

15

/

16

34

3

/

4

69

1

/

2

76

1

1

/

4

3-F 3-F

10

12

36

24

74

7

/

8

(114.1) (88.3) (176.5) (193.0)

(3.2)

(7.6)

(7.6) (25.4) (30.5)

(91.4)

(60.9) (190.2)

AB-120

54

3

/

16

34

3

/

4

69

1

/

2

85

3

/

8

1

1

/

4

3-F 3-F

10

12

36

24

74

7

/

8

(137.6) (88.3) (176.5) (216.8)

(3.2)

(7.6)

(7.6) (25.4) (30.5)

(91.4)

(60.9) (190.2)

AB-150

63

1

/

2

34

3

/

4

69

1

/

2

94

3

/

4

1

1

/

2

3-F 3-F

10

12

36

24

74

7

/

8

(161.3) (88.3) (176.5) (260.7)

(3.8)

(7.6)

(7.6) (25.4) (30.5)

(91.4)

(60.9) (190.2)

AB-200

78

15

/

16

34

3

/

4

69

1

/

2

110

2

3-F 3-F 10 16

1

/

2

36

24

74

7

/

8

(200.5) (88.3) (176.5) (279.4)

(5.1)

(7.6)

(7.6) (25.4) (41.9)

(91.4)

(60.9) (190.2)

AB-250

94

7

/

16

34

3

/

4

69

1

/

2

125

1

/

2

2 3-F 3-F

12

15

36

24

74

7

/

8

(239.9) (88.3) (176.5) (318.8)

(5.1)

(7.6)

(7.6) (30.5) (38.1)