TROUBLESHOOTING (cont.)
PROBLEM
Brew cycle will not start (cont.)
(CWT-APS, CWTF-APS, CWT-TS,
CWTF-TS)
Water is not hot
PROBABLE CAUSE
REMEDY
5. Timer
6. Solenoid Valve
7. Water strainer/flow control
(.222 GPM)
1. Tank Heater Switch
2. Limit Thermostat
CAUTION - Do not eliminate or
bypass limit thermostat. Use
only BOM replacement part
#04680.0000
3. Control Thermostat
4. Tank Heater
Refer to
Service
- Timer for
testing procedures. See page 22
Refer to
Service
- Solenoid Valve
for testing procedures. See page
18
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/flow
control and check for obstruc-
tions. Clear or replace.
Refer to
Service
- Tank Heater
Switch for testing procedures.
See page 21
Refer to
Service
- Limit Thermo-
stat for testing procedures. See
page 16
Refer to
Service
- Control
Thermostat for testing
procedures. See page 15
Refer to
Service
- Tank Heater
for testing procedures. See page
19