75.1038 V3 Jun 2005 [Rev. June 10, 2005]

Page 7 of 8


PROGRAMMING
GUIDE Cont.


MANUAL SET-UP


TROUBLE-
SHOOTING

































If a remote control is not available, you can adjust the sensitivity parameter ONLY, by means of the push
buttons + (Plus) and - (Minus).

The sensor parameters that are not accessible manually will remain at the factory preset values. Pressing the two push buttons,
located on the circuit board, simultaneously for at least two seconds, will restore all default values.

































The door will not open & LED does not
light up

1.

Check supply voltage: 12 to 24 VAC:

± 10%

12 to 24 VDC: -10% / +30%
2.

Check power connector

The sensor does not respond to the
remote control

1.

Check remote control battery insertion

2.

Check remote control battery voltage

The sensor does not respond to the code
entered with the remote control

1.

Remove the cover and press the 2 buttons
simultaneously for at least two seconds. This will reset
the lock code to 0000. Then press the unlock button to
enable you to access the settings with the remote control.

The door open and closes constantly

1.

Increase the tilt angle of the antenna

2. Reduce

sensitivity

DETECTION MODE

3

Detection mode offers 3 different levels of
detection: Bi-directional, Uni-directional and
Uni-directional with MTF (motion tracking
feature). MTF allows the Eagle to switch
from uni-directional to bi-directional upon
detection from the normal approach
direction.

After pressing the DETECTION MODE
key, the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly.

IMMUNITY

1 = Bi-directional
2 = Uni-directional
3 = Uni-directional with MTF

Immunity alters the detection of unwanted
disturbances within the field of motion
detection

.

1 = Extreme sensitivity
2 = Normal Sensitivity
3 = Reduced sensitivity

2

After pressing the IMMUNITY key, the
red LED flashes quickly. After pressing
a number button, the red LED flashes
slowly.

DEFAULT VALUE

1 = Restores default values for all
functions
2 = Boost Mode; Restores default
values for all functions, and increases
sensitivity for high-mount applications

.

After pressing the DEFAULT VALUE
key, the red LED flashes quickly. After
pressing a number button, the red LED
flashes slowly.

KEY USER’S ACTIONS DEFAULT LED STATUS

+ Press to increase
sensitivity by one unit

-

Press to decrease sensitivity

by one unit.

Advertising