Installation location

Install the appliance in a dry, well

ventilated room. The installation location

should neither be exposed to direct

sunlight nor near a heat source, e. g.

a cooker, radiator, etc. If installation next

to a heat source is unavoidable, use

a suitable insulating plate or observe

the following minimum distances to a

heat source:

3 cm to electric or gas cookers.

30 cm to an oil or coal-fired cooker.

Observe ambient

temperature

and ventilation

Ambient temperature

The appliance is designed for a specific

climatic class. Depending on the climatic

class, the appliance can be operated at

the following room temperatures.
The climatic class can be found on

the rating plate, Fig.

+.

Note
The appliance is fully functional within

the room temperature limits

of the indicated climatic class.

If an appliance of climatic class SN

is operated at colder room temperatures,

the appliance will not be damaged up to

a temperature of +5 °C.

Ventilation

The air on the rear panel of

the appliance heats up. Conduction of

the heated air must not be obstructed.

Otherwise, the refrigeration unit must

work harder. This increases power

consumption. Therefore: Never cover

or block the ventilation openings!

Connecting

the appliance

After installing the appliance, wait at least

1 hour until the appliance is switched on.

During transportation the oil in

the compressor may have flowed into

the refrigeration system.
Before switching on the appliance for

the first time, clean the interior of

the appliance (see chapter “Cleaning

the appliance”).

Electrical connection

The socket must be near the appliance

and also freely accessible following

installation of the appliance.
The appliance complies with the

protection class I. Connect the appliance

to 220–240 V/50 Hz alternating current

via a correctly installed socket with

protective conductor. The socket must

be fused with a 10 to 16 A fuse.
For appliances operated in non-

European countries, check whether the

stated voltage and current type match

the values of your mains supply match

the values of the mains supply. This

information can be found on the rating

plate. Fig.

+

Climatic class

Permitted ambient

temperature

SN

+10 °C to 32 °C

N

+16 °C to 32 °C

ST

+16 °C to 38 °C

T

+16 °C to 43 °C