Must include a shutoff valve:
An individual shutoff valve must be installed within
six (6) feet (1.8 m) of the washer/dryer in accordance with
the National Fuel Gas Code, ANSI Z223.1/NFPA 54. The
location should be easy to reach for opening and closing.

Burner input requirements:

Elevations up to 10,000 ft (3,048 m):

The design of this washer/dryer is certified by CSA
International for use at altitudes up to 10,000 ft (3,048 m)
above sea level at the Btu rating indicated on the model/serial
number plate. Burner input adjustments are not required when
the dryer is operated up to this elevation.

Elevations above 10,000 ft (3,048 m):

When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft (305 m) increase in elevation.

Gas supply pressure testing

The washer/dryer must be disconnected from the gas supply
piping system during pressure testing at pressures greater
than ½ psi.

Dryer gas connection

This washer/dryer is equipped with its own permanent,
flexible gas connector, design-certified by CSA International,
for connecting the washer/dryer to the gas supply line.

Flexible gas connector

Venting Requirements

WARNING:

To reduce the risk of fire, this washer/dryer

MUST BE EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling or a concealed space of a building.

If using an existing vent system

Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.

Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.

Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.

If this is a new vent system

Vent material

Use a heavy metal vent. Do not use plastic or metal foil vent.

4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.

DURASAFE™ vent products can be purchased from your
dealer or by calling Whirlpool Parts and Accessories. For more
information, see the “Assistance or Service” section of the
Washer/Dryer User Instructions.

Rigid metal vent

For best drying performance, rigid metal vents are
recommended.

Rigid metal vent is recommended to avoid crushing and
kinking.

Flexible metal vent

Flexible metal vents are acceptable only if accessible for
cleaning.

Flexible metal vent must be fully extended and supported
when the dryer is in its final location.

A. Gas shutoff valve
B.

¹⁄₈" NPT minimum plugged tapping

C. ½" NPT gas supply line
D. Gas supply line coupling 34" (86.4 cm) min.

to 37" (94 cm) max. from floor

A

B

C

D

4" (10.2 cm) heavy metal exhaust vent

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death
or fire.

4"

10.2 cm