Bunn G9-2 HD-S User Manual

Page 8

Advertising
background image

8

TROUBLESHOOTING (cont.)

Problem

Grinder will not start.

Grinder will not shut off.

Remedy

(A) Plug-in the grinder.

(B) Check the voltage at the wall
outlet with a voltmeter. It must
be 120 volts ac for 120V models and
230 volts ac for 230V models.

(A) Momentarily press the Off/On/
Start switch to the “START” (lower)
position.

(B) Refer to

Service

- Off/On/Start

switch for testing procedures. See
page 11.

Refer to

Service

- Timer for testing

procedures. See page 17.

Refer to

Service

- Relay for testing

procedures. See page 14.

Remove the cover plate located on
the right side of the housing. Press
the red “Reset” button. Listen care-
fully for a “click”. This resets the
motor protection circuit and indi-
cates that an overload may have
been encountered by the motor. (An
overload can occur when something
other than coffee is inserted into the
hopper for grinding.) Refer to

Ser-

vice

Motor for disassembly proce-

dures. See page 12.

Refer to

Service

- Motor for testing

procedures. See page 12.

(A) Place the switch in the “OFF/
STOP” position.

(B) Refer to

Service

- Off/On/Start

Switch for testing procedures. See
page 11.

Refer to

Service

- Timer for testing

procedures. See page 17.

Refer to

Service

- Relay for testing

procedures. See page 14.

Probable Cause

1. No power or incorrect voltage

2. Off/On/Start switch

3. Timer

4. Relay

5. Motor overload protector

6. Motor

1. Off/On/Start switch

2. Timer

3. Relay

10218 031603

Advertising
This manual is related to the following products: