Bryant 583A User Manual

Page 22

Advertising
background image

TYPICAL WIRING SCHEMATIC — 208/230-3-60 SHOWN

LEGEND

AHA

— Adjustable Heat Anticipator

BR

— Blower Relay

C

— Contactor

CAP

— Capacitor

COMP

— Compressor Motor

CR

— Combustion Relay

CS

— Centrifugal Switch

EQUIP — Equipment
FS

— Fusible Link

FU

— Fuse

GND

— Ground

GV

— Gas Valve

GVR

— Gas Valve Relay

HS

— Hall Effect Sensor

HV

— High Voltage

I

— Ignitor

IDM

— Induced-Draft Motor

IFC

— Indoor-Fan Contactor

IFM

— Indoor-Fan Motor

IGC

— Integrated Gas Unit Controller

L1

— Line

LS

— Limit Switch

LS1

— Limit Switch

MGV

— Main Gas Valve

NEC

— National Electrical Code

OFM

— Outdoor-Fan Motor

QT

— Quadruple Terminal

RS

— Rollout Switch

SEN

— Sensor

SW

— Switch

TRAN — Transformer

Field Splice

Terminal (Marked)

Terminal (Unmarked)

Splice

Splice (Marked)

Factory Wiring
Field Control Wiring
Field Power Wiring
Accessory or Optional Wiring
To Indicate Common Potential
Only, Not to Represent Wiring

NOTES:
1. If any of the original wires furnished are replaced, they must be replaced with type 90 degree C

wire or its equivalent.

2. See Trade Prices for thermostat and subbases.
3. Use 75 degree C copper conductors for field installation.
4. For high speed IFM, disconnect RED wire from IGC terminal BM and connect BLK wire from IFM.

For medium speed, disconnect RED wire from IGC terminal BM and connect BLU wire from IFM.