PHYSICAL DATA

MODEL

ERVBBLHA1150

ERVBBLHA1200

Port Locations

Sides

Sides

Core Type

Enthalpic transfer media, cross flow

Enthalpic transfer media, cross flow

Weight — lb (kg)

74 (33.6)

76 (34.5)

Shipping Weight — lb (kg)

78 (35.4)

80 (36.3)

Shipping Dimensions in. (mm)

Height

Width

Length

19.75 (502)

20.5 (521)

40.5 (1029)

19.75 (502)

20.5 (521)

40.5 (1029)

MODEL

ERVBBLHA1150

ERVBBLHA1200

Capacity—CFM @

0.5-0.3ESP (in. wc)

60---148

60---183

Efficiency (Sensible)—Percent

32_F (0_ C)

---13_F (---25_ C)

60

49

58

41

Efficiency (Latent)—Percent

@ all temperatures

58

53

Cooling Season Total Recovery Efficiency 95_F

(35_C)

56

52

MODEL

ERVBBLHA1150

ERVBBLHA1200

Voltage

120

120

Max Power — watts

150

240

Max Amps

1.3

2.1

METHODS TO SIZE ERVs

METHOD 1

1. Calculate cu ft of occupied space.
2. Multiply by recommended air changes per hr (AC/h).
3. Divide by 60 minutes per hr to convert to CFM.

Example:
2000 sq ft with 8 ft ceiling, 0.35 air changes per hr (AC/h)
(2000 sq ft x 8 ft ceiling x 0.35 AC/h) / 60 min/h = 93.3 CFM

METHOD 2

1. Multiply number of people times 15 CFM/person.
2. Multiply number of bath rooms 20 CFM/each.
3. Add 25 CFM for kitchen.

Example:
2 people, 2 baths, 1 kitchen
(2 x 15) + (2 x 20) + 25 = 95 CFM