Bosch DSDA ISCSI DISK ARRAY SERIES DSA-S5B50 User Manual
Page 31

DSDA iSCSI Disk Array Series
Monitoring and Maintenance | en
29
Bosch Security Systems
Installation Guide
V 1 | 2008.08
1.
Upload the new software to a Web server
–
If you are using VRM, place the file that contains the new version in
C:\Program Files\Bosch\Video Recording Manager\VRM Server\web
on your VRM Server.
–
If you are not using VRM, start a Web server tool, for example MiniWebServer.exe,
select a root directory and copy the new software version into this root directory.
Example screen:
2.
Download and install the new version on the storage controller hard disks:
Connect to the console of the storage device. To connect to the console, select Filer >
Use Command Line in the navigation panel of the FilerView administration interface.
–
If you are using VRM:
On the console, enter
software install http://username:password@<VRM Server IP>/
<Filename>
Replace <username> and <password> with the login information of your VRM server.
Replace <VRM Server IP> with the IP address of your VRM server and <Filename>
with the name of the file that contains the new version.
Wait a few minutes for the installation to complete.
–
If you are using MiniWebServer.exe:
On the console, enter software install http://<MiniWebServer>/<filename> and
replace <filename> with the name of the software update file.
Wait until the success message displays: Installation of setup.exe-7.xxx_e.exe
completed.
3.
Download the new software to the CF card:
On the console, enter: download.
Wait until the success message displays: Operator requested download completed.
4.
On the console, enter: halt.
The system reboots and stops at the bootloader.
Note that no data can be written on the disks while the system is rebooting.