Bunn espress, Troubleshooting, Es•2a™/es•2sa – Bunn ES2SA User Manual

Page 14

Advertising
background image

BUNN

Espress™

ES•2A™/ES•2SA™

12

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department at 1-800-637-8606.

•

Inspection, testing, and repair of electrical equipment should be performed only by qualified service
personnel.

•

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.

•

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.

•

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

•

This brewer is heated at all times unless disconnected from the power source. Keep away from
combustibles.

WARNINGS

•

Exercise extreme caution when servicing electrical equipment.

•

Disconnect the brewer from the power source when servicing, except when specified.

•

Follow recommended service procedures.

Advertising