Step 4: connect electric, Connect electric, Warning – Bosch HDS256U User Manual

Page 5

Advertising
background image

Ranges are dual rated for use on either 120/240 VAC or 120/208

VAC. See table for power ratings and circuit breaker sizes based

upon the supply voltage for each mode (See chart below).

4. Connect Electric

Step 4: Connect Electric

RISK OF ELECTRIC SHOCK FRAME GROUNDED TO NEUTRAL OF APPLIANCE THROUGH A LINK GROUNDING

THROUGH THE NEUTRAL CONDUCTOR IS PROHIBITED FOR NEW BRANCH-CIRCUIT INSTALLATIONS, (1996 NEC)

MOBILE HOMES AND RECREATIONAL VEHICLES, OR IN AN AREA WHERE LOCAL CODES PROHIBIT GROUNDING

THROUGH NEUTRAL CONDUCTOR. FOR INSTALLATIONS WHERE GROUNDING THROUGH THE NEUTRAL CONDUC-

TOR IS PROHIBITED:

(1) DISCONNECT THE LINK FROM THE NEUTRAL.

(2) USE GROUNDING TERMINAL OR LEAD TO GROUND UNIT: AND

(3) CONNECT NEUTRAL TERMINAL OR LEAD TO BRANCH CIRCUIT NEUTRAL IN USUAL MANNER

(WHEN THE APPLIANCE IS CONNECTED BY MEANS OF A CORD KIT, USE 4 CONDUCTOR

CORD FOR THIS PURPOSE).

WARNING

CONSULT YOUR INSTRUCTIONS FOR ‘ELECTRICAL CONNECTION PROCEDURES’. COPPER WIRE MUST BE USED

FOR CONNECTION TO THE TERMINAL BLOCK. WHEN POWER SUPPLY CORD KIT IS USED TO CONNECT RANGE TO

THE POWER SUPPLY. USE ONLY CORD KITS RATED 120/240 VOLTS MINIMUM AND MARKED FOR USE WITH RANGES.

REFER TO INSTALLATION INSTRUCTIONS FOR PROPER CORD KIT AMPERAGE RATING, RISK OF FIRE OR

ELECTRICAL SHOCK MAY BE INCURRED IF AN INCORRECT SIZE RANGE CORD KIT IS USED, THE INSTALLATION

INSTRUCTIONS ARE NOT FOLLOWED, OR THE STRAIN RELIEF BRACKET IS DISCARDED.

Figure 5

Remove ground

strap from terminal

block. Install with

care, the green

ground wire as

shown at left. Attach

ground wire and

strap with screw

provided with strap.

Center or white wire

must always be

attached to the

central terminal on

block.

All screw and nut

connections must be

tight.

Electrical Connection Procedures
Refer to Figures 5-10 ( below and next page) for further explanation.

Page 4

This appliance may be connected to the power supply by installing

flexible conduit or a power cord set. The electrical rating of the

power cord set (not supplied) must be 240 volt, 30 amperes. The

power cord set shall be marked “For Use with Ranges.”

The power supply shall be connected to the range terminal block

compartment located near the bottom of the back panel (See

Figure 4 , at right). It is accessible by removing the terminal block

cover.

TO PREVENT ELECTRICAL SHOCK, THE GROUNDING PRONG

SHOULD NOT, UNDER ANY CIRCUMSTANCES, BE CUT OR RE-

MOVED. IT MUST BE PLUGGED INTO A MATCHING GROUNDING

TYPE RECEPTACLE AND CONNECTED TO A CORRECTLY POLAR-

IZED 240-VOLT CIRCUIT. A separate circuit is recommended

which is in compliance with the NEC.
If there is any doubt as to whether the wall receptacle is prop-

erly grounded, have it checked by a qualified electrician.

VOLTS

HZ

RATING

CIRCUIT

A.C.

KW

BREAKER

120/240

60

12.1

30 AMPS

120/208

60

9.1

25 AMPS

CAUTION: make certain that gas shutoff valve and all

burner controls are in OFF position before beginning.

The strain relief provided with your range cord

must be properly installed.

Place strain relief in knockout below terminal block (See Figure

4

below). Feed range cord through hole and strain relief up to

terminal block. Allow for slack in the cord between the strain

releif and terminal block. Once cord length/ slack has been

adjusted, attach strain relief per instructrions included with strain

relief. Connect wiring as described below and on next page.

Figure 4

Electric Connection

(found behind terminal

block cover)

Gas Connection

Feed Range

Cord Through

Strain Relief in

Knockout

Panel Here

TIP

The knockout panel can be removed from the range to

install the strain relief:

Remove panel from range, install strain relief in panel

and re-attach.