Bosch 3931 User Manual

Page 11

Advertising
background image

-11-

RESETTING THE CIRCUIT BREAKER

1. Switch off the power tool

2. Press the circuit breaker button.

3. Restart the vacuum cleaner in the desired

mode.

WET VACUUMING

Your 3931 can also be used for wet
vacuuming.

Do not use to vacuum
flammable liquids, gases,

or explosive dusts, like gasoline or other
fuels, lighter fluid, varnish, polyurethane
coatings, cleaners, oil-based paints,
natural gas, hydrogen, coal dust,
magnesium dust, grain dust, or gun
powder.
Electric motors create sparks,
which may ignite the dust or fumes.

1. Before wet vacuuming, run the vacuum in

the PULSE-CLEAN™ mode.

2. Empty the canister to prevent encrustation

when wet vacuuming. If bag is in canister,
remove it as well.

Notes:

• Empty the canister before wet vacuuming.

• Do not use a dust bag when wet

vacuuming

• The filter cartridge must be used when

wet vacuuming.

• Do not activate the PULSE-CLEAN™

mode when the contents of the vacuum
cleaner are wet.

• The unit is equipped with water level

sensors. The unit switches off when the
maximum filling height is reached. The
unit still has power, but will not operate.
The unit must be first switched off before
it can be switched on again.

• When the unit is shut off, some water may

flow out of the hose.

• To prevent siphoning or spillage, lift the

suction hose out of the liquid before
draining the vacuum cleaner.

• Before opening and emptying, move the

switch to the OFF position.

• Always disconnect the vacuum cleaner

cord from the power supply.

• In order to avoid mildew, after wet

vacuuming, remove both filter cartridges
and allow them to dry thoroughly, Dry the
filter and canister thoroughly so that dust
cannot adhere to moist parts. Also remove
the control unit and allow it to dry, too.

• Use a dry filter for subsequent dry

vacuuming. We suggest purchasing extra
filter cartridges when frequently
alternating between wet and dry
vacuuming and swap them out as
appropriate.

Clean the canister and accessories with
water. Wipe the top section with a moist
cloth.

WATER-LEVEL SENSOR MAINTENANCE

Clean the water level sensors occasionally:

See Figure 6.

1. Unlock the canister latches and remove

the control unit.

2. Clean the water level sensors with a soft

cloth.

3. Reattach the control unit again

4. Lock the canister latches.

EMPTYING THE CANISTER

1. Switch the unit off.

2. Disconnect from the power supply.

3. Open the canister latches.

4. Remove control unit.

5. Remove the paper filter bag; dump out the

canister, or drain out the canister as
appropriate.

CANISTER MAINTENANCE

Wipe out the canister from time to time with
a commercially available, non-scouring
cleaning agent and allow to dry.

LEVEL

SENSOR

FIG. 6

!

WARNING

BM 2610919254 12/02 12/18/02 10:52 AM Page 11

Advertising