Belkin F6C550-AVR User Manual

Page 2

Advertising
background image

Software Installation (Installation Optional)

A)

To fully utilize the UPS and its software, your computer

must be able to operate the following operating systems:

Windows98/ ME/ NT4/ 2000 / 2003/ XP and have a USB

port.

B)

Your UPS features the Bulldog Plus Shutdown Software.

This allows you to protect and save your data should a

power outage occur, as well as safely shutdown your

computer in your absence. Please be sure to close out of

all applications prior to installing the software.

1. To install the software, please place the CD into the CD

drive of your computer.

2. Your computer should autorun the CD. If this does not

occur, go to the Run feature on your Start icon (lower left

corner) on your screen. Please enter the CD drive, it may

be D: Upon entering the drive run setup.exe. to execute

the software. Should you continue to have a problem,

please refer to your computer’s owner’s manual for the

correct drive.

3. The “Welcome to the Belkin Bulldog Plus Product

Installation Browser” will appear. Please click Install and

select the Windows version.

4. The Bulldog Plus Installation window will appear. Please

choose the appropriate software to install.

5. Install Shield Wizard will appear onscreen, click Next.
6. Please read the License Agreement and click Yes.
7

On Setup Type, ALL (Standalone) is the default.

Standalone is for UPS management for your computer

only. Networking management is for administrators who

need to manage several UPSes in a workstation

environment. You should not install the networking files

unless you are technically qualified to use these features.

For more information on networking, please refer to the

software user’s manual.

8. On Choose Destination Folder, you have the option to

choose the location of where you would like the Software

located on your computer. We recommend using the

default option as shown on screen. To use the default

option, click Next.

9. On Select Program Folder, you have the option to

choose the program folder for your Software. We

recommend using the default option as shown on screen.

To use the default option, click Next.

10. On the Select Language screen, please select your

language choice.

11. The software will now be installed. Once completed,

please click Finish.

Note!

Please refer to the help feature found on the Belkin On-line

Screen. To access this screen, please click the Belkin shield

found in the lower right corner on your task bar of your

screen.

Once the Belkin On-line screen appears, choose help. The

Bulldog Online Help screen will appear. You may use the

Contents, Index or Search tabs to assist you with your help

issues and to get more information on the specific features

and functions of the software.
C) User Manual Installation

You will need Adobe Acrobat Reader to review the User’s

Manuals. If you do not have the reader, please goto

www.adobe.com to download a free version of the software.
1. From the “Welcome to the Belkin Bulldog Plus Product

Installation Browser” window, locate and choose User

Manual’s.

2. The “Bulldog Plus User Manuals” window will appear.

Please move your pointer to the manual you wish to

open and click.

3. An Adobe PDF file will be opened. To save a copy to

your hard drive, you will need to goto “File” on your menu

bar and choose “Save a copy”.

4. On the Save a Copy window, please choose a

destination folder for the manual.

D) Uninstall for Windows 98/ Me/ NT4/ 2000 / 2003/ XP

There are two options to uninstall the Belkin Shutdown

Software.

Option 1

1. Click the Start icon in the lower left hand corner of your

screen and goto the Programs folder. Scroll to the Belkin

Bulldog Plus folder and choose setup. Install Wizard

will appear.

2. Choose Remove and click Next.
3. The Program Files and Audio Files will be checked. If

they are not, please check them. Click Next. The

uninstall procedure will begin.

4. Click Finish when complete.

Option 2
(Note: Windows2000/ 2003/ XP users choose the

Control panel function from your Start icon and then

goto to step 2.)

1.

Click the Start icon in the lower left hand corner of your

screen and goto the Settings icon. Goto and choose

the Control Panel folder. The Control Panel window will

appear.

2.

Locate and click the Add/Remove Programs icon. The

Add/Remove Programs window will appear.

3. Locate and choose the Belkin Bulldog Plus software.

Click the Change/Remove button on the right. Install

Wizard will appear.

4.

Choose Remove and click Next.

5. The Program Files & Audio Files will be checked. If

they are not, please check them. Click Next. The

uninstall procedure will begin.

6.

Click Finish when complete.


TECHNICAL SPECIFICATIONS

MODEL

F6C550-

AVR

F6C750-

AVR

F6B750-

AVR

Capacity

550VA /

330W

750VA / 400W

Voltage Range

90-136Vac

INPUT

Frequency

60HZ ( ±3HZ )

Voltage

Simulated sine wave, 120vac±

10%

OUTPUT

Frequency

(On battery)

60HZ ( ±1HZ )

Back up time

Full / half load

2-8

mins

1.5-5

mins

1.5-5

mins

BATTERY

Typical

Recharge Time

12hours recover 85%

capacity

ENVIRONMENT

Ambient

operation

0~85% humidity

non-condensing, 0~35℃

Safety

UL / c-UL, FCC class B

CONFORMANCE

Surge

IEEE C62.41 Category A

standard

Dimension

(W X H X D)

4.57 x 8.98 x 12.95 inches

(116 x 228 x 329 mm)

PHYSICAL

Net weight

6.6kgs/

14.52lbs

7.1kgs/

15.62lbs

All specifications are subject to change without prior notice.

STORAGE

Storage Conditions
Store the UPS covered and upright in a cool, dry location with its
battery fully charged. Before storing, charge the UPS for at least
four hours. Disconnect any cables connected to the computer
interface port to avoid unnecessary drainage of the battery.
Extended Storage
During extended storage in environments where the ambient
temperature is +5

o

F to +86

o

F, charge the UPS battery every six

months. During extended storage in environments where the
ambient temperature is +86

o

F to +113

o

F, charge the UPS battery

every three months.
Note:


BELKIN COMPONENTS USER LICENSE AGREEMENT

Belkin Components (Belkin”) thanks you for choosing one of our
products. This User License Agreement (Agreement”) contains the
terms and conditions under which limited use of the product is
licensed to you.
PLEASE READ THIS NOTICE CAREFULLY. DO NOT USE THE
SOFTWARE OR PRODUCT UNTIL YOU HAVE READ AND
AGREED TO THIS AGREEMENT. IF YOU USE THE SOFTWARE
AND PRODUCT, YOU ARE AGREEING TO THE TERMS AND
CONDITIONS SET OUT IN
THIS AGREEMENT. IF YOU DO NOT ACCEPT THESE TERMS
AND CONDITIONS, YOU MUST RETURN THE UNOPENED
PRODUCT WITH THE DISKS INSIDE TO THE PARTY FROM
WHOM YOU RECEIVED IT.
SCOPE OF USE: In this Agreement, software means all
machine-readable software programs and associated files in this
package. All modified versions of and upgrades or improvements to
such programs and all copies of such programs and files. You, a
single user opening this envelope (You or our), may use the
software on a single central processing unit. You may not rent it,
loan it out, or lease it, nor use it on a multi-user system.
LICENSE: You have the non-exclusive right to use the software.
You are not permitted to copy, modify or transfer the software or
documentation. You may not compile, disassemble or otherwise
reverse engineer, breakdown, analyze or modify the software.
USE AND RESTRICTIONS: You are permitted to make backup
copies of all the software disks for archival purposes only. You must
reproduce the proprietary notice set forth on the disks and affix
them to all backup copies. You are not permitted to use these
programs in connection with a computer service, or to use the
backup copies other than as a replacement for the original copy.
TERM: This license is effective upon acceptance by opening this
envelope or in any other way using the enclosed software, which will
constitute your acceptance of, and agreement to, this Agreement,
and is effective until terminated. The limited license in this
Agreement will be automatically terminated if you fail to comply with
any of the Terms and conditions in this Agreement. You agree that
upon such termination you will immediately destroy all programs and
documentation, including all copies made or obtained by you.
SOFTWARE, PROGRAM, DOCUMENTATION, AND ANY
RELATED INFORMATION, GOODS OR SERVICES ARE
PROVIDED WITH NO WARRANTY OR REPRESENTATION OF
ANY KIND WHAT SO EVER. BELKIN HEREBY DISCLAIMS ALL
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING
BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE.
The entire risk of the use, results and performance of the software,
program and documentation is borne by you. Should any or all of the
product, software, program, documentation, or related information,
goods or services be defective, misused, unsuitable or cause or give
rise to any harm or liability whatsoever, you, not Belkin or its
associates, dealers or agents, assume the entire liability, cost of
repair, correction or any payment or other remedy whatsoever.
Furthermore, no warranty or guarantee is made regarding the use or
results of the product, software, program, documentation, or any
related information, goods or services in terms of correctness,
accuracy, reliability, timeliness or otherwise. You use and rely on

the program at your own risk. The following is the only and
exclusive warranty and remedy of any kind: Belkin does
warrant that the program disks are free from physical defects in
materials and workmanship under normal use for a period of
one (1) year from the date of purchase, as evidenced by a copy
of the sales receipt. Return the defective disk or
documentation with your receipt directly to Belkin for a
replacement.
DISCLAIMER: Belkin or its associates will in no event be
liable (i) in any amount for lost profits or special, incidental,
punitive or consequential damages, or (ii) for any claim or
damage of any nature, or under any theory, whatsoever, in
any amount in excess of the purchase price you paid for the
product. The warranties and remedies here set forth are
exclusive, and in lieu of all others oral or written, express or
implied. Some jurisdictions do not allow exclusion or limitation
of implied warranties or of liability for incidental damages, so
the foregoing limitations or exclusion may not apply to you.
This warranty gives you specific legal rights, which vary from
jurisdiction to jurisdiction.
HOWEVER, YOU WAIVE SUCH RIGHTS, EXCEPT AS
EXPRESSLY PROVIDED UNDER THE TERMS AND
CONDITIONS OF THIS AGREEMENT, TO THE MAXIMUM
EXTENT ALLOWED BY LAW.
The license is governed by the laws prevailing in the State of
New York, without regard to its conflicts of laws principles.
ACKNOWLEDGMENT:
By opening the package on which this Agreement is printed,
or through which it is visible, you acknowledge that you have
read this Agreement, understand it, and agree that this
agreement is the complete and exclusive statement of
agreement between yourself and Belkin and supersedes any
prior agreements, oral or written, and any other
communications relating to the subject matter of this
Agreement.
SEVERABILITY:
Any term or provision of this Agreement or any application
thereof, which may be prohibited or unenforceable by law in a
particular jurisdiction, shall be interpreted and enforced to the
maximum extent allowed in such jurisdiction (which the parties
acknowledge could mean severing the provision from this
Agreement or, if allowed, enforcing it in a narrower form),
without affecting the remainder of this Agreement, or any
other application of such term or provision in such jurisdiction,
or application of such term or provision in any jurisdiction.

SAFETY INFORMATION

CAUTION!

Internal battery voltage is 12V DC.

The unit is intended for installation in a controlled

environment (temperature controlled, indoor area free of

conductive contaminants).

All batteries used are Sealed Lead Batteries. Batteries must

be recycled.

Recycling Information
Your UPS contains a Non-spillable Sealed Lead Battery. On
the battery, you will find the battery name. Please reference
the chart below for recycling information.

Battery Name

Recycling
Inside the
USA

Recycling Outside
the USA

BB Battery

(800) 278-8599

N/A

CSB Battery

(800) 738-7372

1 (817) 244-4415

VISION Battery

(973) 726-5323 N/A

RITAR Battery

(888) 841-5179

N/A

TROUBLE SHOOTING

PROBLEM

POSSIBLE CAUSE

SOLUTION

On/ Off /Test button

not pushed or pushed

less than 2 second

Press the On/Off

/Test button for more

than 2 seconds

Battery voltage is too

low

Recharge the UPS at

least eight hours

UPS not on,

LED not lit

UPS fault

Contact service

personnel

Power cord loose

Re-plug the power

cord

AC breaker is burned

out or tripped

Replace or reset the

breaker

UPS always

on battery

mode

Ac utility voltage is too

high or too low, or

black out

Normal condition

Battery not fully

charged

Recharge the UPS at

least eight hours

UPS is overload

Remove some

un-necessary loads

Back up time

too short

Charger fault or other

reason

Replace battery.

Contact belkin.com

The UPS

continuously

beeps

Overload

Remove the

non-critical loads

Red LED lit

Battery failure

Replace battery.

Contact belkin.com

CONTACT US

Belkin Components, Ltd

501 West Walnut St.

Compton, CA • 90220-5221 USA

Tel: 310.898.1100

Fax: 310.898.1111

Belkin Components, Ltd

Unit 13 • Gatelodge Close •

Round Spinney

Northampton, NN3 8RX UK

Tel: +44 (0) 1604678300 •

Fax: +44 (0) 1604678330

Belkin Components B.V.

Starparc Building Boeing

Avenue 3331119 PH

Schiphol-Rijk The Netherlands

Tel: +31 (0) 20 654 73 00

Fax: +31 (0) 20 654 73 49

Belkin Australia Ltd

7 Bowen Cresent

West Gosford, NSW 2250

Tel: +61 (02) 4325 4666

Fax: +61 (02) 4325 4277

Please visit

www.Belkin.com

for battery replacement information.

Away from sunlight Away from heat Away from

Advertising
This manual is related to the following products: