Troubleshooting – Bunn WDG-2 User Manual

Page 11

Advertising
background image

11

Problem

Grinder will not start.

Remedy

(A) Plug-in the grinder.

(B) Check the voltage at the wall
outlet with a voltmeter. It must
be 120 volts ac.

(A) Momentarily press the Off/On/Start
switch to the “START” (lower) position.

(B) Refer to

Service - Off/On/Start

switch for testing procedures. See page
13.

Refer to

Service - Timer for testing pro-

cedures. See page 16.

Refer to

Service - Weight Control Board

for testing procedures. See page 18.

Remove Grinder rear cover. Press the
red “Reset” button, one located on rear
of each motor. Listen carefully for a
“click”. This resets the motor protec-
tion circuit and indicates that an over-
load may have been encountered by the
motor. (An overload can occur when
something other than coffee is inserted
into the hopper for grinding.) Refer to
Service - Motors for disassembly pro-
cedures. See page 14.

Probable Cause

1. No power or incorrect voltage

2. Off/On/Start switch

3. (A) Timer - DG-2

(B) Weigh Control Board WDG-2

4. Motor overload protector

TROUBLESHOOTING

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.

•

Inspection, testing, and repair of electrical equipment should be performed only by qualified
service personnel.

•

All electronic components have 120 volt ac and low voltage dc potential on their terminals.
Shorting of terminals or the application of external voltages may result in board failure.

•

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be
permanent. If an intermittent condition is encountered, the cause will likely be a switch contact
or a loose connection at a terminal or crimp.

•

Make certain that all electrical connections are tight and isolated.

WARNING

•

Exercise extreme caution when servicing electrical equipment.

•

Turn power OFF when servicing, except when electrical tests are specified.

•

Follow recommended service procedures.

•

Replace all protective shields or safety notices.

10854 030300