2 of 3, The ntu-1 in typical applications, Features – Black Box NTU-1 User Manual

Page 2: Overview

Advertising
background image

2 of 3

9/19/2007
#11512

724-746-5500

blackbox.com

FEATURES

• Point-to-point or point-to-multipoint

configuration.

• Up to 18,000 feet (5500 meters)

operating distance.

• Easy configuration—everything you

need is on the rear panel.

• Uses standard RJ-45 jacks on all

interfaces.

• Operates automatically.

• For wallmount or desktop use.

• Power supply is included.

The NTU-1 in typical applications.

OVERVIEW

ISDN service requires an NT1 to connect the terminal

adapter to the ISDN line. If your terminal adapter doesn’t
have a built-in NT1, the NTU-1 is your affordable choice.

The NTU-1 converts the 2-wire echo-canceled 2B1Q code

from the central office to a Customer Premise 4-wire alternate
space inversion code. It supports both point-to-point and
point-to-multipoint configuration. All options and connec-
tions are accessible on the rear panel, and the NTU-1 comes
with surge protection. Also, all interfaces have standard RJ-45
jacks.

Power Information:

Wallmount Transformer—

The NTU-1 is normally powered from the wallmount

transformer. The transformer and the NTU-1 power-supply
circuitry provide 5 watts for up to two terminal devices
connected to the S/T interface. Connect the transformer’s
barrel connector to the Power jack on the rear panel. Plug
the transformer into a standard 120-VAC wall socket.

Signal Power—

The NTU-1 routes local and remote power to the signal

leads of the S or T interface. For phantom powering
applications, S/T interface connector pins 4 and 5 (Transmit)
are the negative power leads, and pins 3 and 6 (Receive) are
the positive power leads.

Remote Power—

The NTU-1 can receive backup power over the U interface

connector. The input must be a minimum of 48 VDC and
5 watts. Both local and backup power is routed to the S/T
interface connectors to power the associated terminal
equipment. Pins 7 and 8 on the U interface provide remote
power to both S/T jacks and the NTU-1.

S/T Interface

(100 ohms IN)

Multipoint S/T

Interface

(100 ohms IN)

Multipoint

S/T Interface

ISDN U Interface

from Telco

(100 ohms IN)

ISDN U Interface

from Telco

(100 ohms IN)

ISDN U Interface

from Telco

(100 ohms IN)

TE

TE

TE

TE

TE

NTU-1

(IS200A-R2)

NTU-1

(IS200A-R2)

NTU-1

(IS200A-R2)

100 ohms IN on either one of the units,

and OUT on the other

100 ohms IN on unit with

longest cable

100 ohms IN on unit with

longest cable

Up to 1 km

Up to 1 km

Passive Bus
Connection

Point-to-point

connection