Using the Web Configuration and Management Interface

Manual Documentation Number ES1A -2907m

pn6909-rev003

17

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Park – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

TCP Sockets

Select TCP Sockets to implement Direct IP Mode using TCP. When using
TCP Sockets your converter can be configured as a TCP server or TCP
client
.

TCP Server Settings

If your ES1A is configured as a TCP server, other network devices
can initiate a TCP connection with the serial device connected to the
ES1A serial port. (This is also referred to as reverse telnet.) Network
devices initiating connections must be configured with the IP
address of the ES1A and the TCP port number associated with its
serial port.

After selecting TCP Sockets, click Apply to return to the Serial
Port Configuration
page. Select the TCP Server Settings as
required by your application.

Figure 9.

TCP Server Settings

For each option, the TCP port number is shown. You can also
Enable TCP Keep Alive for each selection. (If Enable Keep Alive
is selected the connections is maintained even if no data is being
sent.)

TCP Client Settings

If your ES1A is configured as a TCP client it will automatically
establish a bi-directional TCP connection between the serial device
and a server or other networked device. Selecting Automatically
establish TCP connections
enables this feature and its
configuration options become available.