Description of hardware, Sfp slots – Brocade Communications Systems Brocade 6910 Ethernet Access Switch 53-1002580-01 User Manual

Page 18

Advertising
background image

4

Brocade 6910 Ethernet Access Switch Hardware Installation Guide

53-1002580-01

Description of Hardware

1

Description of Hardware

The Brocade 6910 switches consist of two model types, one hardened for extended temperature
range environments, the other non-hardened for standard temperature range environments:

Standard temperature range switches for 0 to +50 °C:

BR-6910-EA-AC

BR-6910-EA-DC

Extended temperature range switches for -40 to +65 °C:

BR-6910-EA-H-AC

BR-6910-EA-H-DC

SFP Slots

The 12 Small Form Factor Pluggable (SFP) transceiver slots are shared with 12 RJ-45 ports. In its
default configuration, if an SFP transceiver (purchased separately) is installed in a slot and has a
valid link on its port, the associated RJ-45 port is disabled and cannot be used. The switch can also
be configured to force the use of an RJ-45 port or SFP slot, as required.

There are two types of SPF transceivers - one hardened that can operate at temperatures between
-40 to +65 °C, and non-hardened that can operate at temperatures between 0 to +50 °C.

The SFP slots support the following SFP transceivers:

Standard temperature range optics (0 to +50 °C)

100Base-SX (OM) 33225-100

100Base-LX (OM) 33226-100

1000Base-SX (OM) 33210-100

1000Base-LX (OM) 33211-100

1000Base-LHA (OM) 33212-100

1000Base-LHB 33004-000

1000Base-BXU 33006-000

1000Base-BXD 33005-000

1000Base-CWDM

Extended temperature range optics (-40 to +65 °C)

100Base-FX (OM) 33224-100

1000Base-SX (OM)

1000Base-LX (OM)

1000Base-LHA (OM)

For information on the recommended standards for fiber optic cabling, see

“Fiber Optic Devices”