Service (cont.) – Bunn FMD-1 FMD-2 User Manual

Page 36

Advertising
background image

36

J1

SERVICE (cont.)

FIG. 37 DISPENSE SOLENOID VALVE

TERMINALS

P1672

Remove panel and set aside.

3. Remove the two #8-32 securing the auger motor

mounting panel to the dispenser housing and the
two rear #8-32 screws from the side panels.

4. Tilt auger motor mounting panel forward allowing

access to the dispense valve(s).

5. Remove the wires from the solenoid valve.
6. Turn-off the water supply to the dispenser.
7. Drain enough water from the tank so the water

level is below the dispense valve mounting hole.

8. Disconnect the water line from the solenoid valve.
9. Remove the #10-32 screw securing the solenoid

valve to side of the tank. Remove solenoid valve.

10. Using the #10-32 screw install new solenoid valve

on side of the tank

11. Push the water line onto the tube on bottom of

solenoid valve.

12. Refer to Fig. 37 and reconnect the wires.
13. Reassemble auger and hopper components.

SOLENOID VALVE (DISPENSE) - FMD-1 & FMD-2
(cont.)

SOLENOID VALVE (INLET) - FMD-1 & FMD-2

FIG. 38 INLET SOLENOID VALVE

Location:

The inlet solenoid is located on the lower right

side of the rear panel.

Test Procedures:
1. Disconnect the dispenser from the power source.
2. Disconnect the white and violet wires from the

solenoid valve.

3. Check the voltage across the white and violet wires

with a voltmeter. Connect the dispenser to the
power source. The indication must be 120 volts ac
for two wire 120 volt models, three wire 120/208
and 120/240 volt models.

4. Disconnect the dispenser from the power source,

If voltage is present as described, proceed to #5
If voltage is not present as described, refer to the
wiring diagram and check dispenser wiring harness.

5. Check for continuity across the solenoid valve coil

terminals.

If continuity is present as described, reconnect the
white and violet wires to the solenoid.
If continuity is not present as described, replace the
solenoid valve.

6. Check the solenoid valve for coil action. Connect

the dispenser to the power source. Listen carefully
in the vicinity of the solenoid valve for a "clicking"
sound as the coil magnet attracts.

P1665

RED to Main Harness

WHI to Main Harness

RIGHT

LEFT

ORN to Main
Harness

WHI to Main
Harness

TAN to Main Harness

WHI to Main Harness

FMD-1

FMD-2

29112 011906