To load individual modules from an existing preset, please press the PAGE key

to go to the second page of the MEMORY menu. Similar to page 1, you can

select a preset from which you want to load a module. Turn the lower data

wheel to select the module of your choice (GEQ, PEQ, DEQ, WIDTH, DYN and

I/O). Then, press the large data wheel or the B key to load the module

(RECALL MODULE). Here, too, you will be prompted to confirm your selection.
Additionally, STORE MODULE (A key) allows you to store individual modules in

an existing preset.

Exception:
DUAL MONO modules cannot be stored in a STEREO preset.

3.10 METER menu

The METER key below the two 7-digit LED displays selects the METER menu

comprising three pages and giving you an overview of all input/output levels of

the DEQ2496.

Fig. 3.33: METER menu (page 1)

Page 1 of the METER menu shows the levels of the left and right stereo side.

Use the A key (SOURCE) to determine whether the input signal, the output signal

or the signal applied to the digital or AUX output shall be displayed. The two bars

in the middle of the display show the average level of the signals in the form of

a VU meter. This means that the displays respond with some delay to changes in

signal level. Thus, very short peaks will not be displayed (RMS).
The outer two displays are peak meters indicating the signal level including

all peaks. As a consequence, the levels shown here are always a bit higher

than those displayed by the VU meter. The signal peaks of all level meters

(including peak hold) are shown to the right of these displays (PEAK). Press the

B key (CLEAR PEAK) to reset the peak values and recalculate them.

If the input/output signal overloads, the corresponding LEVEL meter
will read “CLIP” (PEAK). In this case, reduce the input/output level.

Fig. 3.34: METER menu (page 2)

The SPL meter (Sound Pressure Level) can be found on page 2 of this menu.

In combination with a measuring microphone (e.g. BEHRINGER ECM8000),

this meter allows you to measure volume levels. SPL also features a peak

hold display, and with the B key you can reset and recalculate the peak

value (CLEAR PEAK).

The correct setting of the microphone sensitivity must be ensured
(see chapter 3.11). We recommend our measurement microphone
BEHRINGER ECM8000, which features an input sensitivity of -37 dBV/Pa.

The A key (WEIGHT) adjusts various dB weighting routines for the calculation of

the signal level (dB (A), dB (C) or OFF).

Fig. 3.35: METER menu (page 3)

Page 3 of the METER menu provides a virtual VU meter, as known from analog

processors or mixing consoles.

3.11 RTA/MIC input

Use this input to feed a microphone or line signal (separate from the main input)

into RTA or SPL meter. Information on how this is done is found on page 1 of the

UTILITY menu.

3.11.1 Connecting a measurement microphone
Select MIC LEVEL as input sensitivity on RTA/MIC. If you are using a condenser

mic, you need to activate phantom power (MIC LEVEL +15 V). On RTA/MIC MIC

LEVEL, adjust the sensitivity of the mic you are connecting. If you are using the

BEHRINGER ECM8000, this value is -37 dBV/Pa.

3.11.2 Connecting a line signal
Select LINE LEVEL as input sensitivity on RTA/MIC INPUT. Adjust the desired input

sensitivity under RTA/MIC LINE LEVEL. The preset value is 0 dBFS or 120 dB SPL.

4. Applications

The universal concept of the BEHRINGER ULTRACURVE PRO with its multitude

of audio processing functions opens up a whole range of applications. A few

examples with typical settings will be described in the following.

4.1 Sum-signal equalizer for live applications

This application is the most probable use of the ULTRACURVE PRO.

XENYX 2222FX

Stereo output L + R

ULTRACURVE PRO DEQ2496

Inputs L + R

Outputs L + R

EP2000

Left

Right

B1520 PRO

B1520 PRO

Fig. 4.1: The ULTRACURVE PRO as sum-signal equalizer

Advertising