Stop end pipes – Liebherr HS 8100 HD Litronic User Manual
Page 17
17
Stop End Pipes
Technical Data
Stop end pipes
mm
500
600
800
1000
1200
1500
Wall thickness
mm
15
15
15
18
18
20
Length 2.5 m
kg
700
841
1149
1595
1926
2552
Length 5.0 m
kg
1162
1394
1889
2705
3263
4412
Length 10.0 m
kg
2082
2498
3368
4927
5936
8132
Length 15.0 m
kg
3002
3602
4847
7148
8609
11852
Lifting caps*
Length
mm
1050
1050
1125
1150
1150
1150
Weight
kg
209
251
362
412
454
630
Shoes
Length
mm
720
720
720
720
720
720
Weight
kg
230
276
368
471
567
710
General Remarks
Stop End Pipes
The tube connections (bayonet fitting) are manu-
factured from high-strength steel and are machined
after rolling. Because of higher quality material and
adequately dimensioned wall thicknesses with addi-
tional stiffenings, the stop end pipes have proven to
be very effective for the construction of diaphragm
walls up to 60 m depth.
The tube connections can easiliy be connected,
they have a radial fit and are interchangeable.
Stop end pipes 1000 m prior to shipment
By means of the uncoupling device which we have
developed as an accessory for our tube extracting
machines, the tube connections can be opened
and closed fully automatically which means that the
time for the installation and removal of the stop end
pipes can be reduced considerably.
*for previous design only