9

Appliance dimensions

(mm)

Setting up

• Do not place the appliance in direct sunlight or near cookers,

radiators and similar sources of heat.

• The floor on which the appliance stands should be horizontal and

level. To compensate for any unevenness, adjust the height of the

feet with the open-ended spanner supplied.

Do not cover ventilation openings

or grille.

• Do not place heat-emitting appliances, e.g.

microwave oven, toaster, etc., on top of the

freezer.

• Standard EN 378 specifies that the room in

which you install your appliance must have

a volume of 1 m

3

per 8 g of R 600a refriger-

ant used in the appliance, so as to avoid the

formation of inflammable gas/air mixtures in

the room where the appliance is located in the

event of a leak in the refrigerant circuit. The quantity of refrigerant

used in your appliance is indicated on the type plate on the inside

of the appliance.

GB

G 20 H = 1250 mm

G 24

H = 1447 mm

G 27

H = 1644 mm

Operating and control elements

1

Temperature display (display)

2

Temperature button

3

On/Off button

4

SuperFrost button

5

Audible warning on/off button

Setup mode is activated (activating the child lock and

adjusting the display brightness)

Alarm (symbol flashes if the temperature inside the

appliance is too high)

Child lock is activated

SuperFrost is on

Adjusting the display brightness (this symbol is only

activated in setup mode)

Demo mode is activated

Climate rating

The climate rating indicates the room tem-

perature at which the appliance may be

operated in order to achieve full refrigeration

performance.
The climate rating is indicated on the type

plate.
The position of the type plate is shown in

the section entitled Description of the appliance.

Climate rating

Room temperature

SN

+10°C to +32°C

N

+16°C to +32°C

ST

+16°C to +38°C

T

+16°C to +43°C

SN-ST

+10°C to +38°C

SN-T

+10°C to +43°C

Do not operate the appliance outside the speci-

fied room temperature range.

Electrical connection

Only operate the appliance with alternating current (AC).

The permissible voltage and frequency are indicated on the type

plate. The position of the type plate is shown in the section entitled

Description of the appliance.

The socket must be properly earthed and protected by a fuse.

The tripping current of the fuse must be between 10 A and 16 A.

The socket must not be situated behind the appli-

ance and must be easily accessible.

Do not connect the appliance using an exten-

sion cable or extension socket.
Do not use stand-alone inverters (conversion

of direct current to alternating current/three-

phase current) or energy-saving plugs. Risk

of damage to the electronic control system!

• Do not store explosives or sprays using combusti-

ble propellants such as butane, propane, pentane,

etc. in the appliance. Electrical components might

cause leaking gas to ignite. You may identify such

sprays by the printed contents or a flame symbol.

• Do not use electrical appliances inside the appli-

ance.

• The appliance is designed for use in enclosed

areas. Do not operate the appliance outdoors or

in areas where it is exposed to splash water or

damp conditions.

1