GENERAL
System Description
Furnish a _________________ (4-way multipoise) dual capac-
ity gas-fired condensing furnace for use with natural gas or pro-
pane (factory authorized conversion kit required for propane);
furnish cold air return plenum; furnish external medial cabinet for
use with accessory media filter or standard filter.
Quality Assurance
Unit will be designed, tested and constructed to the current ANSI
Z 21.47/CSA 2.3 design standard for gas-fired central furnaces.
Unit will be 3rd party certified by CSA to the current ANSI Z
21.47/CSA 2.3 design standard for gas-fired central furnaces.
Unit will carry the CSA Blue Star® and Blue Flame® labels.
Unit efficiency testing will be performed per the current DOE test
procedure as listed in the Federal Register.
Unit will be certified for capacity and efficiency and listed in the
latest GAMA Consumer's Directory of Certified Efficiency
Ratings.
Unit will carry the current Federal Trade Commission Energy
Guide efficiency label.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer's recommendations.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only. Warranty certificate available upon
request.
PRODUCTS
Equipment
Components shall include: slow-opening dual rate gas valve to
reduce ignition noise, regulate gas flow, with electric switch gas
shut-off; flame proving sensor, hot surface igniter, pressure
switch assembly verifies inducer operation; flame rollout switch,
drain tubing and installed condensate drain trap, blower and in-
ducer assembly, 40va transformer; low-voltage (heating) (heat-
ing/cooling) thermostat.
Blower Wheel and Blower Motor
Galvanized blower wheel shall be centrifugal type, statically and
dynamically balanced. Blower motor of PSC type shall be per-
manently lubricated with sealed bearings, of _____ hp, and shall
be multiple-speed direct drive. Blower motor shall be soft mount-
ed to the blower scroll to reduce vibration transmission.
Filters
Furnace shall have reusable-type filters. Filter shall be ______ in
(x) ______in. An accessory high efficiency Media Filter is avail-
able as an option _____________Media Filter.
Casing
Casing shall be of .030 in. thickness minimum, pre-painted gal-
vanized steel.
Two Speed Inducer Motor
Two Speed Inducer motor shall be soft mounted to reduce vibra-
tion transmission.
Primary Heat Exchangers
Primary Heat exchangers shall be 3-Pass 20 gauge corrosion
resistant aluminized steel of fold-and-crimp sectional design,
which operates under negative pressure.
Secondary Heat Exchangers
Secondary Heat exchangers shall be of a flow-through design
having a patented interior laminate coating of polypropylene for
greater corrosion resistance with fold-and-crimp design, which
operates under negative pressure.
Controls
Controls shall include a microprocessor based integrated elec-
tronic control board with at least 11 service troubleshooting
codes displayed via diagnostic flashing LED light on the control,
has ability to store fault codes, when activated a self-test feature
checks all major functions of the furnace within one minute, and
a replaceable automotive-type circuit protection fuse. Multiple
operational settings available including, separate blower speeds
for low heat, high heat, low cooling, high cooling and continuous
fan. Continuous fan speed may be adjusted from the thermostat.
Cooling airflow will be selectable between 350 or 400 CFM per
ton of air conditioning. Features will also include temporary re-
duced airflow in the cooling mode for improved dehumidification
when a Thermidistat® is selected as the thermostat.
Operating Characteristics
Heating Capacity shall be _________ Btuh input;
____________ Btuh output capacity.
Fuel Gas Efficiency shall be 93% AFUE.
Air delivery shall be __________ cfm minimum at 0.50 in. wg.
external static pressure.
Dimensions shall be: depth __________ in.; width __________
in.; height _________ in. (casing only). Height shall be
__________ in. with A/C coil and ____________ in. overall with
plenum.
Electrical Requirements
Electrical supply shall be 115 volts, 60 Hz, single-phase (nomi-
nal). Minimum wire size shall be _________ AWG; maximum
fuse size or HACR-type, designated circuit breaker shall be
_______ Amps.
Special Features
Refer to section of the product data sheet identifying acces-
sories and descriptions for specific features and available
enhancements.
GUIDE SPECIFICATIONS