COMBINATION RATINGS Continued

* Ratings are net values reflecting the effects of circulating fan heat. Supplemental electric heat is not included. Ratings are based on:

Cooling Standard:

80°F (27°C) db 67°F (19°C) wb indoor entering air temperature and 95°F (35°C) db air entering outdoor unit.

High-Temp Heating Standard:

70°F (21°C) db indoor entering air temperature and 47°F (8°C) db 43°F (6°C) wb air entering outdoor unit.

Low-Temp Heating Standard:

70°F (21°C) db indoor entering air temperature and 17°F (–9°C) db 15°F (–10°C) wb air entering outdoor unit.

† Outdoor section/indoor section combination tested in accordance with DOE test procedure for heat pumps.
‡ Based on computer simulation. TXV must be Puron compatible and hard shutoff type.

** In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance.

Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. All Bryant furnaces are equipped with TDR except for the
394HAD.

†† Indoor Airflow

COP

— Coefficient of Performance

EER

— Energy Efficiency Ratio

HSPF

— Heating Seasonal Performance Factor

SEER

— Seasonal Energy Efficiency Ratio

TC

— Total Capacity (Btuh)

TDR

— Time-Delay Relay

TXV

— Thermostatic Expansion Valve

UNIT

SIZE-

SERIES

INDOOR

UNIT

CFM††

ARI STANDARD RATINGS*

Cooling

Heating

TC

Seasonal Efficiency SEER

EER

High-Temp

Low-Temp

HSPF

Factory-
Supplied

Enhance-

ment

Standard

Rating

Field-Supplied

Accessory‡

Puron

TXV

Puron TXV

& TDR**

TC

COP

TC

COP

048-A,C

CJ5A/CK5A/CK5BA060

1400

45,000

NONE

—

—

12.50

10.75

48,000

3.50

28,600

2.38

8.20

CJ5A/CK5A/CK5BN060

1400

45,500

NONE

—

—

13.00

10.90

48,500

3.52

28,600

2.38

8.25

CJ5A/CK5A/CK5BX060

1400

45,500

NONE

—

—

13.00

10.90

48,500

3.52

28,600

2.38

8.25

CK3BA060

1400

45,000

NONE

—

—

12.50

10.75

48,000

3.50

28,600

2.38

8.20

060-B,C

FV4ANB006†

1750

58,000

TDR&TXV

13.00

—

—

10.75

60,000

3.56

37,000

2.54

8.00

FB4ANB070

1750

57,000

TDR

—

12.00

—

10.20

60,000

3.44

37,800

2.46

7.80

FC4BNB070

1750

57,000

TDR

—

12.00

—

10.20

60,000

3.44

37,800

2.46

7.80

FK4CNB006

1750

58,000

TDR

—

12.80

—

10.75

59,500

3.56

37,000

2.54

8.00

FX4ANB060

1750

57,000

TDR&TXV

12.00

—

—

10.20

60,000

3.44

37,800

2.46

7.80

CC5A/CD5AW060

1750

56,000

NONE

—

—

12.50

10.45

58,500

3.26

36,800

2.42

7.50

CJ5A/CK5A/CK5BX060

1750

56,500

NONE

—

—

12.50

10.55

59,000

3.44

37,000

2.50

7.70

Advertising