128

Brocade BigIron RX Series Hardware Installation Guide

53-1002483-03

Displaying flash memory and version information

6

Displaying version information

You can display version information for a BigIron RX Series switch using the e command as shown
in the following:

BigIron RX# show version

HW: BigIron RX Router

Boot-Monitor Image

Indicates the boot image installed in the management module’s boot flash.
The image name format is described in

“Software image naming

conventions”

on page 123. The output displays the following information

about the image:

Version – “2.3.0Txxy” indicates the image version number. The “Txxy”
is used by Brocade for record keeping. The “xx” indicates the hardware
type, while the “y” indicates the image type.

Size – The size, in bytes, of the image.

Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.

Compilation date and time – The date and time that Brocade compiled
the image.

Interface Modules

Line Card Slot <number>

The interface module for which flash information is displayed.
The <number> parameter indicates the number of the chassis slot, 1 – 16,
in which the interface module is installed.

Code Flash

The model number and size of the interface module’s code flash.

IronWare Image (Primary or
Secondary)

Indicates the IronWare image installed in the primary or secondary location
in the interface module’s code flash. The image name format is described
in

“Software image naming conventions”

on page 123. The output displays

the following information about the image:

Version – “2.3.0Txxy” indicates the image version number. The “Txxy”
is used by Brocade for record keeping. The “xx” indicates the hardware
type, while the “y” indicates the image type.

Size – The size, in bytes, of the image.

Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.

Compilation date and time – The date and time that Brocade compiled
the image.

Boot Flash

The model number and size of the interface module’s boot flash.

Boot-Monitor Image

Indicates the boot image installed in the interface module’s boot flash. The
image name format is described in

“Software image naming conventions”

on page 123. The output displays the following information about the
image:

Version – “2.3.0Txxy” indicates the image version number. The “Txxy”
is used by Brocade for record keeping. The “xx” indicates the hardware
type, while the “y” indicates the image type.

Size – The size, in bytes, of the image.

Check sum – A unique ID for the image. If the contents of the image
change, the check sum changes also.

Compilation date and time – The date and time that Brocade compiled
the image.

TABLE 23

Code flash and boot flash information (Continued)

This field...

Displays...

Advertising