Bunn espress™ model es•1a, Troubleshooting – Bunn ES.1A User Manual

Page 16

Advertising
background image

BUNN

Espress™

Model

ES•1A™

14

A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems

encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department at 1-800-637-8606.

•

Inspection, testing, and repair of electrical equipment should be performed only by qualified service
personnel.

•

Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.

•

The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will
help to avoid twists and kinks in the tubing.

•

Make certain that all plumbing connections are sealed and electrical connections tight and isolated.

•

This brewer is heated at all times unless disconnected from the power source. Keep away from
combustibles.

•

All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.

•

Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If
an intermittent condition is encountered, the cause will likely be a switch contact or a loose connection
at a terminal or crimp.

WARNINGS

•

Exercise extreme caution when servicing electrical equipment.

•

Disconnect the brewer from the power source when servicing, except when specified.

•

Follow recommended service procedures.

•

Replace all protective shields and safety notices.

TROUBLESHOOTING

Problem

Equipment will not
operate

Brew cycle will not start

Pushing any of the
automatic batch buttons
results in only a short
flash of the brew light.
Will not brew. Continu-
ous brew works as well
as automatic refill.

Probable cause

No power or incorrect
voltage

Toggle switch (Master
on/off)

No water

Water strainer or water
conditioner

Dose sizes were set
with a defective flowme-
ter. The result was no
flow pulses reached the
electronic controller.
during the dose size
programming.

Remedy

Connect the brewer to the power
source. Check for proper voltages.
Check circuit breaker/fuse.

Must be in the on position. Pilot
lamp will light.

Check plumbing and shut off
valves.

Direction of flow arrows must be
pointing toward the brewer.

Remove the strainer and/or filter
cartridge of the water conditioner
and check for obstructions. Clear
or replace.

Replace flowmeter. Repair loose
connector in wiring between
flowmeter and electronic controller.

Advertising