CALIBRATING THE DISPENSER (Cont.)

LCD DISPLAY

CALIBRATION MODE

DESCRIPTION

Right (Decaf) Water Rate

Set PRIME-NORMAL-RINSE switch to

RINSE position. Press and hold Decaf

Dispense Switch until flow stops (20

sec.) Refer to Field Calibration of the

Concentrate Pumps.

Right (Decaf) Water Rate

Enter Liters collected from the 20 sec.

test above.

Default = 1.08

Range = 0.95 - 1.12 Liters

Pump “OFF” Delay

Delays the Pump turn off after a

dispense.

Default = 200

Range = 1 - 999 mSec.

Reset Factory Defaults

Resets all set up values to the Factory

Default setting.

Hold both Increase (+) and Decrease

(-) switch for 10 seconds.

Displays Software Version # -

Exits To Home View After 3 Seconds.

English or Metric Mode

Eng for English

S.I. for Metric

Error Code History

Displays last known Error Code

Depress the Decrease (-) to view the

last 3 Errors.

Hold the Decrease (-) & Increase (+)

switches for 10 sec. to Erase.