4

CONTROL MUTING

A control is provided on each ST55.2 amplifier to allow remote switching of mute on/off. The preamplifier’s control
output, such as is provided with B&K series preamplifiers, can be utilized to provide a control signal to the ST55.2.
If more than one amplifier is being controlled, the control signal can be extended to include each successive unit
by simply running an RCA type audio cable from the CTRL OUT connector of the first amplifier to the CTRL IN
connector of the next unit (commonly referred to as ‘daisy chaining’). An example of how to connect two amplifiers
is illustrated in the figure below.

If a source other than a B&K series preamplifier is used to control multiple amplifiers, only the control output
voltage from the source is critical. It must be within the range, as indicated on the rear panel, 5-24 volts DC is
required. The amplifier will provide each successive amplifier with a control voltage of 12 volts DC for reliable
operation. The amplifiers control output may be used as a source of 12 VDC @ 125 mA for other user
applications as well.

DO NOT POWER MOTORS WITH THIS CIRCUIT.

WHEN SWITCH IS SET TO ENABLE, THE
AMPLIFIER WILL ONLY OPERATE WHILE
A 5-24VDC SIGNAL IS APPLIED TO CTRL IN

WHEN SWITCH IS SET TO ENABLE, THE
AMPLIFIER WILL ONLY OPERATE WHILE
A 5-24VDC SIGNAL IS APPLIED TO CTRL IN

DEFEAT

CTRL IN

ENABLE

CTRL IN

ENABLE

CONTROL I/O

CTRL

OUT

CTRL

OUT

12VDC

125mA

12VDC

125mA

CTRL

IN

CTRL

IN

WHEN SWITCH IS SET TO ENABLE, THE
AMPLIFIER WILL ONLY OPERATE WHILE
A 5-24VDC SIGNAL IS APPLIED TO CTRL IN

WHEN SWITCH IS SET TO ENABLE, THE
AMPLIFIER WILL ONLY OPERATE WHILE
A 5-24VDC SIGNAL IS APPLIED TO CTRL IN

DEFEAT

CTRL IN

ENABLE

CTRL IN

ENABLE

CONTROL I/O

CTRL

OUT

CTRL

OUT

12VDC

125mA

12VDC

125mA

CTRL

IN

CTRL

IN

Daisy Chain To
Other Amplifiers

Rear View of
Second Amplifier
with Control I/O

Rear View of
First Amplifier
with Control I/O

From Preamplifier
Control Output

Control Enable

Button OUT

If the control function is desired, each unit in the system must remain connected at all times and the control must
be enabled. To enable the control function, the CTRL ENABLE button must be out for each controllable amplifier
in the system. For more information on the amplifiers output status under various control conditions, refer to the
table below.

@ CTRL IN

Button position

Output status

@ CTRL OUT

Signal

OUT

Sound

Signal

Signal

IN

Sound

Signal

No Signal

OUT

Mute/Standby

No Signal

No Signal

IN

Sound

Signal


*Note: The control voltage is for muting control only. Each amplifier must be connected to its own source of AC
power in order for it to operate.