Server Properties Configuration

Manual Documentation Number: ESP901-902-3704

Chapter 5

37

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

Port Status

This field indicates whether a serial port is connected via the

Serial

Server

to a virtual COM port of a device on the network.

TCP/UDP Port

This sets the port number for connection. The default port number for
the

ESP901

is

4000

. The default port numbers for the

ESP902

are

4000

and

4001

for serial ports 1 and 2 respectively.

In all modes of operation,

Direct IP

or

Virtual COM

, the port number

set in the

Server Properties

menu must match the

Virtual COM

or

socket software port settings.

N

N

o

o

t

t

e

e

:

:

Example: The Virtual COM default setting is TCP/UDP Port 4000. If

the port # property is changed to 4001, the virtual COM port will have

to be changed to 4001. The hardware settings can be changed from

the ESP Manager or Console Configuration Menu. The Virtual COM

port setting also can be changed within the Device Manager of the
computer on which it is installed.

Serial Port Mode

Serial Port Mode

allows configuration of the serial server for the

following modes of operation:

Console

– When this mode is selected and the server is updated, a

PC running a communications program such as HyperTerminal can
communicate with the

Serial Server

via the

Console Mode

serial

port (the serial Port on ESP901 or Port 1 on ESP902), displaying
the

Server Properties

screen and allowing configuration of the

server and its ports.

Upgrade

– When this mode is selected and the server is updated,

firmware can be uploaded into the

Serial Server

via the

Console

Mode

serial port or a virtual COM port mapped to the number of

the

Console Mode

serial port.

Default

– When this mode is selected and the server is updated, it

will revert the server to its default configuration.

RS-232

– When this mode is selected and the server updated, the

selected serial port will become an RS-232 serial port on the
server.

RS-422

– When this mode is selected and the server updated, the

selected serial port will become an RS-422 serial port on the
server.

Server Properties Configuration

38

Chapter 5

Manual Documentation Number: ESP901-902-3704

B&B Electronics Mfg Co Inc – 707 Dayton Rd - PO Box 1040 - Ottawa IL 61350 - Ph 815-433-5100 - Fax 815-433-5104 – www.bb-elec.com

B&B Electronics Ltd – Westlink Commercial Pk – Oranmore, Galway, Ireland – Ph +353 91-792444 – Fax +353 91-792445 – www.bb-europe.com

RS-485

– When this mode is selected and the server updated, the

selected serial port will become an RS-485 serial port on the
server.

Connection At

When the

Connection Mode

field is set to

Client

or

Client (no

heartbeat)

, this field becomes active, allowing the ESP901/902 (acting

as a client) to connect to the server either on

Power up

or on

Data

Arrival

(first character arriving).

Max Connection

This field allows the user to configure the

Serial Server

to have up to

eight TCP connections.

Remote IP Address

This is a security feature activated by entering the IP address of the
desired client. The

Serial Server

will only communicate with the listed

IP address and all other requests for connection will be filtered out. The

Serial Server

must be set up as a

TCP

or

UDP Server

to use this

feature. The default setting is

255.255.255.255

.

If

Paired Mode

is not being used, do not change this setting until the

application has been tested and is communicating properly. Then
activate the address filtering feature.

N

N

o

o

t

t

e

e

:

:

Refer to Chapter 1 Paired Mode

Update/Save

Server properties must be updated separately for each serial port.
Updating varies slightly depending on which of the four configuration
user interfaces are used.

Updating the Server Properties in ESP Manager

From the

Server Properties

screen, click the

Update

button to store

the configuration settings for the currently selected port. The vcomui
dialogue box will appear indicating you must restart the device before
the new settings will take effect. Click

Yes

.

Advertising
This manual is related to the following products: