Operating Instructions

Inspect the visible portion of the hose before each use of the appliance. Inspect the entire hose
assembly at least annually.

Checking for Leaks

Burner Connections

Make sure the regulator valve and hose connections are securely fastened to the burner and
the tank.
If your unit was assembled for you, visually check the connection between the burner pipe and
orifice. Make sure the burner pipe fits over the orifice.

WARNING: Failure to inspect this connection or follow these

instructions could cause a fire or an explosion which can cause death,
serious bodily injury, or damage to property.

Please refer to diagram for proper installation.

If the burner pipe does not rest flush to the orifice, please contact 1.800.762.1142 for
assistance.

Tank/Gas Line Connection

Make 2-3 oz. of leak solution by mixing one part liquid dishwashing
soap with three parts water.

Make sure control knobs are off.

Attach (1) 14.1 oz or (1) 16.4 oz LP gas tank.

Spoon leak check solution at all “x” and arrow locations.

If any bubbles appear disconnect gas tank, reconnect and re-test. If
you continue to see bubbles after several attempts, disconnect LP gas
source and contact 1.800.762.1142 for assistance.

If no bubbles appear after one minute turn tank “OFF”, wipe away
solution and proceed.

Before Turning Gas Supply ON

Your heater was designed and approved for OUTDOOR USE ONLY. DO NOT use it inside a
building, garage, or any other enclosed area.

Make sure surrounding areas are free of combustible materials, gasoline, and other flammable
vapors or liquids.

Ensure that there is no obstruction to air ventilation.

Be sure all gas connections are tight and there are no leaks.

Be sure the access panel is clear of debris.

Be sure any component removed during assembly or servicing is replaced and fastened prior
to starting.

Before Lighting

Heater should be thoroughly inspected before each use, and by a qualified service person at
least annually.

If relighting a hot heater, always wait at least 5 minutes for gas to dissipate.

Lighting

1. Turn control knob to “OFF” position.

2. Turn on gas at LP gas tank.

3. Push in control knob and rotate to “ON” position. This will

activate the built-in ignitor and light the burner. If necessary,
keep depressing and rotating knob until burner lights.

4. Once burner is lit, hold control knob in for at least 30 seconds

and release.

5. If burner does not stay lit, turn to “OFF” position and wait 5

minutes and repeat steps 2
and 3.

6. If ignitor does not light burner, use a lit match positioned against

the bottom of emitter screen at burner location, and repeat steps
2 and 3.

7. Once burner is lit, rotate knob to desired heating level.

If you experience any ignition problem, turn off the heater and gas
supply, and consult “Troubleshooting”.

Caution: Avoid inhaling fumes emitted from the

heater’s first use. Smoke and odor from the burning
of oils used in manufacturing will appear. Both smoke and odor will dissipate
after approximately 30 minutes. The heater should NOT produce thick black
smoke.

Note: The burner may be noisy when initially turned on. To eliminate excessive noise from the

burner, turn the control knob to the “LOW” position. Then, turn the knob to the level of heat
desired.

When heater is “ON”:

Emitter screen will become bright red due to intense
heat. The color is more visible at night.

Burner will display tongues of blue flame. These flames
should not be yellow or produce thick black smoke,
indicating an obstruction of airflow through the burners.

If yellow flame is detected, turn off heater and gas
supply and consult “Troubleshooting”.

Visually check burner flames at each use and make
sure flame height matches illustration.

Re-lighting

Note: For your safety, control knob cannot be turned on
without first depressing control knob in off position and
then rotating to on.

1. Turn gas control knob to off.

2. Wait at least 5 minutes to let gas dissipate before

attempting to relight burner.

3. Repeat the “Lighting” steps 2 and 3.

Turning Off

1. Rotate gas control knob to off position. Normally, burner will make a slight popping sound

when extinguished.

2. Turn off gas at LP gas tank, or unscrew 14.1 oz or 16.4 oz LP gas tank.

3. Remove access panel.

4. Unscrew gas line from regulator.

5. Close access panel.

Note: After use, some discoloration of the emitter screen is normal.

Cleaning and Care

Notices

1. Abrasive cleaners will damage this product.

2. Never use oven cleaner to clean any part of heater.

3. Do not clean any heater part in a self cleaning oven. The extreme heat will damage

the finish.

4. More frequent cleaning may be required as necessary. It is imperative that control

compartment, burners and circulating air passageways of the heater be kept clean.

5. Spiders and insects can create a dangerous condition that may damage heater or

make it unsafe. Keep burner area clean of all spiders, webs, or insects. Clean burner
holes by using a heavy-duty pipe cleaner. Compressed air may help clear away
smaller particles.

6. Inspect heater before each use.

7. Have heater inspected annually and repairs should be made by a qualified service

person.

8. Check heater immediately if any of the following conditions exist:

a. The smell of gas in conjunction with extreme yellow tipping of burner flames.

b. Heater does not reach proper temperature.

Note: At temperatures less than 40ºF, heat output will be reduced.

c. Heater’s glow is excessively uneven

d. Burner makes popping noises during use.

Note: A slight pop is normal when burner is extinguished.

9. Carbon deposits may create a fire hazard. Keep dome and emitter clean at all times.

10. Do not clean heater with combustible or corrosive cleaners. Use warm, soapy water.

11. Do not paint engine, engine access panel or dome.

12. This heater should be thoroughly cleaned on a regular basis.

13. After a period of storage and/or non use, check for leaks, burner obstructions and

inspect for any abrasion, wear, cuts to the hose.

OFF

ON
HIGH

LOW

OFF

ON
HIGH

LOW

Regualtor Connection