FURNACE COMPONENTS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

16

17

18

19

5

15

A07609

Fig. 2 -- Model 355CAV Furnace

1. Combustion--air intake connection to ensure contaminant--

free air (right or left side).

2. Burner sight glass for viewing burner flame.

3. Burner assembly (inside). Operates with energy--saving

inshot burners and hot surface igniter for safe, dependable
heating.

4. Redundant gas valve. Safe and efficient. Features 1 gas

control with 2 internal shutoff valves and one throttling
valve.

5. Vent outlet. Uses PVC pipe to carry flue gas from the

furnace’s combustion system (right or left side).

6. Inducer motor. Pulls hot flue gases through the heat

exchangers, maintaining negative pressure for added
safety.

7. Blower access panel safety interlock switch.

8. Air filter and retainer (location in furnace may vary).

9. Condensate

drain

connection.

Collects

moisture

condensed from burned gases for disposal into home drain
system. (Location in furnace varies.)

10. Heavy--duty blower. Circulates air across the heat

exchangers to transfer heat into the home.

11. Everlastict

Secondary

condensing

heat

exchanger

(inside). Wrings out more heat through condensation.
Constructed with polypropylene--laminated steel to ensure
durability.

12. Primary serpentine heat exchanger (inside). Stretches fuel

dollars with the S--shaped heat--flow design. Solid
construction of corrosion--resistant aluminized steel means
reliability.

13. Furnace control board.

14. 3--amp fuse provides electrical and component protection.

15. Light emitting diode (LED) on furnace control board.

Status code light is for diagnosing furnace operation and
service requirements.

16. Pressure switches ensure adequate flow of flue gas

through furnace and out vent system.

17. Rollout switch (manual reset) to prevent overtemperature.

18. Junction box for 115--v electrical power supply. (May be

located on right or left side)

19. Transformer (24v) behind furnace control board provides

low--voltage

power

to

furnace

control

board

and

thermostat.

Advertising