Bryant 583B User Manual

Page 2

Advertising
background image

—2—

HIGH AND LOW PRESSURE SWITCHES

Evaporator and condenser coils

are computer-designed for

optimum heat transfer and cooling efficiency. The evaporator
coil is fabricated from copper tube and aluminum fins and is lo-
cated inside the unit for protection against damage. The con-
denser coil is internally mounted on the top tier of the unit.
Copper fin coils and pre-coated fin coils are available from the
factory by special order. These coils are recommended in appli-
cations where aluminum fins are likely to be damaged due to
corrosion. They are ideal for seacoast applications.

Low sound ratings

ensure a quiet indoor and outdoor environ-

ment with sound ratings as low as 7.2 bels. (See page 3.)

Easy to service cabinets

provide easy single-panel acces-

sibility to serviceable components during maintenance and
installation. The basepan with integrated drain pan provides
easy ground level installation with or without a mounting pad.
Convenient handholds are provided to manipulate the unit
on the jobsite. A nesting feature ensures a positive basepan
to roof curb seal when the unit is roof mounted. A convenient
3/4-in. wide perimeter flange makes frame mounting on a roof-
top easy.

Downflow operation

is easily provided in the field to allow ver-

tical ductwork connections. The basepan utilizes knockout style
seals on the bottom openings to ensure a positive seal in the
horizontal airflow mode.

Integrated Gas Control (IGC) board

provides safe and efficient

control of heating and simplifies trouble-shooting through its
built-in diagnostic function.

Cabinets are constructed of heavy-duty, phosphated, zinc-
coated prepainted steel capable of withstanding 500 hours in

salt spray. Interior surfaces of the evaporator/heat exchanger
compartment are insulated with cleanable semi-rigid insulation
board, which keeps the conditioned air from being affected by
the outdoor ambient temperature and provides improved indoor
air quality. (Conforms to American Society of Heating, Refriger-
ation and Air Conditioning Engineers No. 62P.) The sloped drain
pan minimizes standing water in the drain, which is provided with
an external drain.

Louvered Grille

provides hail and vandalism protection.

TABLE OF CONTENTS

Page

Features/Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,2
Model Number Nomenclature. . . . . . . . . . . . . . . . . . . . . . . . . . 3
ARI Capacities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,4
Physical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5,6
Options and Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7,8
Base Unit Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9,10
Accessory Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Selection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Performance Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13-15
Typical Piping and Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Application Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Typical Wiring Schematics . . . . . . . . . . . . . . . . . . . . . . . . . 22-24
Controls . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Guide Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27,28

Advertising