SERVICE

This section provides procedures for testing and

replacing various major components used in this

brewer should service become necessary. Refer to

Troubleshooting for assistance in determining the

cause of any problem.
WARNING - Inspection, testing, and repair of electri-

cal equipment should be performed only by qualified

service personnel. The brewer should be unplugged

when servicing, except when electrical tests are re-

quired and the test procedure specifically states to

plug-in the brewer.
COMPONENT ACCESS
WARNING
- Disconnect the brewer from the power

source before the removal of any panel or the replace-

ment of any component.

All components are accessible by the removal of

the top cover, front inspection panel, and rear panel.

CONTROL THERMOSTAT

FIG. 10-1 COMPONENT ACCESS

FIG. 10-2 CONTROL THERMOSTAT

Location:

The control thermostat is located in the hood.

Test Procedures:

1. Disconnect the brewer from the power source.

2. Locate the blue wire on the control thermostat.

3. Check the voltage across the blue/black wire on

the control thermostat and the white wire on the

tank heater on 120V models or red wire on the

tank heater on two wire 200V or 230V models

with a voltmeter. Connect the brewer to the power

source. The indication must be:

a) 120 volts ac for two wire 120 volt models.

b) 200 to 230 volts ac for two wire 200 or 230

volt models.

4. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #5.

If voltage is not present as described, refer to the wiring

diagrams and check the brewer wiring harness.

5. Locate the black wire on the control thermostat.

6. Gently remove the capillary bulb and grommet

from the tank.

7. Check the voltage across the black wire of the

control thermostat and the white wire on the tank

heater on 120V models or red wire on the tank

heater on two wire 200V or 230V models with a

voltmeter when the control thermostat is turned

fully clockwise. Connect the brewer to the power

41722 070209

(CONTINUED)

Advertising