Troubleshooting storage – Belkin P73220uk User Manual

Page 17

Advertising
background image

Troubleshooting

Storage

17

PROBLEM

POSSIBLE CAUSE

SOLUTION

On/off/test/button not
pushed or pushed less
than 3 seconds

Battery voltage less than
10V

UPS fault

Power cord loose

AC breaker is burned out

Line voltage too high, too
low or black out

Battery not fully charged

UPS is overloaded

Charger fault or
other reason

Overload

Battery failure

The UPS continuously
beeps

UPS not on
LED not lit

UPS always at
battery mode

Back up time too short

Red LED lit

Press the on/off/test button
more than 3 seconds

Recharge the UPS at least
4 hours

Contact service personnel

Replug the power cord

Replace the breaker

Normal condition

Recharge the UPS at
least 4 hours

Remove some
unnecessary loads

Replace battery

Remove the
non-critical loads

Replace battery

13.0

Storage Conditions
Store the UPS covered and upright in a cool, dry location, with its battery fully charged.
Before storing, charge the UPS for at least 4 hours. Disconnect any cables connected to
the computer interface port to avoid unnecessary drainage of the battery.

13.1

Extended Storage
During extended storage in environments where the ambient temperature is
-15°C to +30°C, charge the UPS battery every 6 months.
During extended storage in environments where the ambient temperature is
+30°C to +45°C, charge the UPS battery every 3 months.