Use only bissell Replacement filters in your bissell vacuum.

style 7 pre-Motor filter (#203-1013)

style 7 post-Motor filter (#203-1009)

style 7 hepa post-Motor filter (#3207)

Unplug vacuum from electrical outlet.

The Pre-Motor Filter, located in the bottom of the bag compartment, protects the motor

from dirt particles. If filter becomes dirty, lift out filter and clean.

The Post-Motor Filter assists in the filtration process to return clean air to the room. To

remove this filter, open the door on the side of the cleaner. Grasp filter and pull it straight out.

Note: Select Models come with a white, pleated HEPA Media Filter.

This filter is not washable and must be replaced.

The filters may be hand washed in cold water with mild detergent, then air dried.

Reposition filters when completely dry.

you should check your vacuum cleaner’s Rotating floor brush and Drive belt regularly

for wear or damage. you should also clean the brush and brush ends of string, hair, and

carpet fibres. These can wrap around the brush and hamper its ability to effectively

clean your carpet. also remove any debris that has accumulated under the brush cover.

Unplug vacuum from electrical outlet.

Place handle in Low position and turn vacuum over so bottom side is up.

Remove the five screws as shown with a screwdriver. Lift the Brush Cover off.

Grasp Rotating Floor Brush at both ends and lift.

Clean strings, hair and other debris from Rotating Floor Brush,

paying particular attention to brush ends.

Clean strings, hair and other debris from Motor Pulley and Drive Belt areas.

Check Drive Belt carefully for wear, cuts or stressed areas. Replace if worn.

Check Air Passageway for obstructions. Remove debris from this area.

Use only bissell style 7 Replacement belts (#32074) in your

bissell vacuum.

Unplug cleaner from electrical outlet.

With Rotating Floor Brush removed from vacuum cleaner (Steps 1-4 of

Check Rotating Floor Brush and Drive Belt), grasp old Drive Belt and remove

from Motor Pulley. Discard old Drive Belt.

Place new Drive Belt over Motor Pulley and stretch other end over Rotating

Floor Brush in the space between the bristles.

Place ends of Rotating Floor Brush down into slots on sides as shown.

Turn Rotating Floor Brush by hand several times in direction of Motor Pulley. If properly

installed, Drive Belt will centre itself.

Reposition Brush Cover and five screws. Tighten screws securely. Make sure end of

Brush Cover is snapped into place.

Cleaning Pre-Motor & Post-Motor Filters

Check Rotating Floor Brush and Drive Belt

11

WARNING:

To reduce the risk of

injury from moving parts,

turn off vacuum and

disconnect Power Plug

from electrical outlet.

3.

4.

5.

3.

4.

5.

1.

2.

6.
7.
8.

Post-Motor
Filter

Pre-Motor
Filter

Motor
Pulley

Air
Passageway

1.

2.

WARNING:

Do not operate cleaner

with damp or wet filters or

without all filters in place.

Replace Drive Belt

8

3.

4.
5.

1.
2.

6.

Brush

Cover