Brady X-PLUS Series User’s Guide

Press

Display Shows

Action/Explanation

APPLICATOR

PORT

Setting the Applicator Port

Press the RIGHT or LEFT BLACK

OVAL key to display other choices.
Default: Off
Selections: Off, mode 1, mode 2, mode 3, mode 4
Determines the action of the verifier port.
• Off: The applicator port is off.
• Mode 1: Asserts the ~END_PRINT signal low while the printer

is moving the label forward.
• Mode 2: Asserts the ~END_PRINT signal high while the printer

is moving the label forward.
• Mode 3: Asserts the ~END_PRINT signal low for 20

milliseconds when a label has been completed and positioned.

Not asserted during continuous printing modes.
• Mode 4: Asserts the ~END_PRINT signal high for 20

milliseconds when a label has been completed and positioned.

Not asserted during continuous printing modes.

WEB S.

These parameters are automatically set during the calibration

procedure. They should only be changed by a qualified service

technician. Refer to the maintenance manual for more

information on these parameters.
Press the NEXT/SAVE key repeatedly to skip these parameters.

MEDIA S.

RIBBON S.

MARK S.

MARK MED S.

MEDIA LED

RIBBON LED

MARK LED