Display Indications
7
The indicators flashing usually indicates normal char
ging.
The following ar
e only displayed in fault conditions.
STEADY INDICA
TOR LONGER THAN 20 SECONDS
[Condition: T
ravel-Pak unable to supply charge]
Reason
Suggested action
Dummy plug not fitted in unused socket.
Fit plug or connect a second Flash Head.
Thermal cut-out initiated
W
ait for T
ravel-Pak to cool.
www
.bowens.co.uk
Connection Or
der
6
Switch of
f the T
ravel-Pak.
or
AL
TERNA
TE FLASHING INDICA
TORS
[Condition: - Battery V
o
ltage T
oo Low W
ait 5mins for Auto Recovery]
Reason
Suggested action
Battery too low for operation
1.
W
ait for battery voltage to r
ecover slightly
2.
Char
ge Battery (See Instructions).
3.
Fit Ext Battery (See Instructions).
The unit may be br
ought back sooner than 5mins by cycling the power switch, T
ravel-Pak should
not be operated in this condition for longer than necessary
.
F
AST DOUBLE BLINK BOTH INDICA
TORS
[Condition: - Power Saving Mode]
Reason
Suggested action
Power Save after appr
ox 10mins of low activity
1.
Change Either Head Selector Switch.
2.
Change Char
ge Mode Fast/Slow
.
3.
T
u
rn
of
f then back on to r
eset T
ravel-Pak.
It is r
ecommended not to leave your T
ravel-Pak for long periods of time, to wake up the unit change
one of the monoblock power switched on either connected head or change the char
ge rate
Fast/Slow switch. The T
ravel-Pak will r
echeck connected heads and r
esume char
ging again.
Connect Esprit Gemini(s).
Fit Dummy Socket if r
equir
ed.
Switch the Esprit Gemini to Position II.
Switch on the T
ravel-Pak.
1
2
3
4
5