Wiring diagram, Warning – New Buck Corporation 329 User Manual

Page 26

Advertising
background image

WIRING DIAGRAM

NOTE: “If any of the original wire as supplied with the gas appliance must be
replaced, it must be replaced with a wire of at least a 105

o

C. temperature rating.”

NOTE: Installation and repair should be done by a qualified service person.
This heater should be inspected before use and at least annually by a qualified
service person. More frequent cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is imperative that control compartments
and circulating air passageways of the heater be kept clean.


CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can
cause improper and dangerous operation.

Verify proper operation after servicing.

MOTOR

RHEOSTAT

THERMOSTAT

GREEN

JUMPER

WHITE

BLACK

BLACK

JUMPER

JUMPER

POWER CORD

Figure 6

WARNING:

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE

HAZARDS OF HIGH SURFACE TEMPERATURES AND SHOULD STAY AWAY TO
AVOID BURNS OR CLOTHING IGNITION. YOUNG CHILDREN SHOULD BE
CAREFULLY SUPERVISED WHEN THEY ARE IN THE SAME ROOM WITH THE
APPLIANCE

WARNING:

DO NOT PLACE CLOTHING OR OTHER FLAMMABLE

MATERIAL ON OR NEAR THE APPLIANCE.

Page 22