8

CONTROL INPUT AND OUTPUT


A control (trigger) system is provided on both the Reference 200.7 and Reference 200.5 amplifiers to allow
remote switching of the amplifier’s standby on/off feature. The control input is designed to operate with a source
(trigger) of 5-24 volts AC or DC. All B&K A/V processors and preamplifiers may easily be utilized to control this
standby on/off feature.

In addition your amplifier has a control output circuit to allow control of an external device such as another power
amplifier, projection screen, power strip, etc. The control output has the capability to source 12VDC @ 125 mA
(on) or 0 VDC (off).

If more that one amplifier is being controlled, the control output may be extended to include each successive unit
by simply connecting a 1/8” mini-jack cable from the CTRL OUT connector of the first amplifier to the CTRL IN
connector of next unit (commonly referred to as ‘daisy chaining’). An example of how to connect two amplifiers is
illustrated in the diagram below.

Rear view of second

amplifier with control input

Rear view of amplifier

with control input

Daisy chain to
other amplifiers

From preamplifier
rear panel
control output

C O N T R O L I / O

C T R L

I N

C T R L

O U T

1 2 V D C
1 2 5 m A

+

CONTROL IN ALLOWS AMPLIFIER

OPERATION WHEN A 5-24V SIGNAL

IS APPLIED WITH A 3.5mm MINI JACK

C O N T R O L I / O

C T R L

I N

C T R L

O U T

1 2 V D C
1 2 5 m A

+

CONTROL IN ALLOWS AMPLIFIER

OPERATION WHEN A 5-24V SIGNAL

IS APPLIED WITH A 3.5mm MINI JACK

DO NOT POWER MOTORS WITH THE CONTROL OUT CIRCUIT!!!

If the control function is desired, each unit in the system must remain connected at all times and the control must
be enabled. To enable the control function, the CTRL IN jack must have a 3.5mm mini-jack inserted for each
controllable amplifier in the system. For more information on the amplifier’s output status under various control
conditions, refer to the table below.

*Note: The control input voltage is intended for standby on/off control only. For proper amplifier operation, it is
recommended that each amplifier have its own source of AC power.

@ CTRL IN

Button Position

Output Status

@CTRL OUT

Signal OUT Sound Signal

Signal IN

Sound Signal

No Signal

OUT

Mute/Standby

No Signal

No Signal

IN

Sound

Signal










Advertising