Calibration procedure

1.

Use any video pattern generator to output XGA 60Hz PC timing with 32 grayscale pattern.

Enter the factory OSD page 2 and execute ADC Brightness and ADC Contrast.(as Fig. 6)

2. Restore CW delay value and color temperature values.

Verification

Check the version number in the factory OSD page 1.(as Fig. 1)

Fig. 6