% % (OHFWURQLFV 0IJ &R ,QF ±  'D\WRQ 5G  32 %R[   2WWDZD ,/   3K   )D[  ± ZZZEEHOHFFRP

% % (OHFWURQLFV /WG ± :HVWOLQN &RPPHUFLDO 3DUN ± 2UDQPRUH *DOZD\ ,UHODQG ± 3K   ± )D[   ± ZZZEEHXURSHFRP



EIA-232-E (RS-232)

Function

PIN #

DB-

25

DB-

9

TO

DTE

TO

DCE

Shield 1

Transmit Data (TD)

2

3

>

Receive Data (RD)

3

2

<

Request To Send

(RTS)

4 7 >

Clear To Send (CTS)

5

8

<

DCE Ready (DSR)

6

6

<

Signal Ground (SG)

7

5

Received Line Signal

Detector (DCD)

8 1 <

DTE Ready (DTR)

20

4

>

Ring Indicator

22

9

-----

THRESHOLD VOLTAGES

Signal with

Respect to SG

Signal A with Respect to

Signal B

Signal A with Respect to

Signal B

SIGNAL

STATE

RS-232

RS-422

RS-485

"0", Asserted, ON,

Space, Active

+3 to +25 VDC

+2 to +6 VDC (Transmitter)

+0.2 to +7 VDC (Receiver)

+1.5 to +6 VDC (Transmitter)

+0.2 to +12 VDC (Receiver)

"1", Disasserted,

OFF, Mark, Inactive

-3 to -25 VDC

-2 to -6 VDC (Transmitter)

-0.2 to -7 VDC (Receiver)

-1.5 to -6 VDC (Transmitter)

-0.2 to -7 VDC (Receiver)

NOTE: Some RS-422 and RS-485 equipment use "+" and "-" descriptors.