START--UP AND OPERATION

Step 1

—Checking Air Purifier Operation

ELECTRICAL SHOCK AND HIGH VOLTAGE

HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

a. Attach the Perfect Airt Air Purifier door to the cabinet.

A magnet in the door (see Fig. 8) is used to activate a safe-

ty switch in the power supply when the door is installed.

The power supply will not energize the air purifier unless

the safety switch is activated.

b. Turn the HVAC system power on and adjust the thermo-

stat or Evolutiont System Control to activate the system

fan.

c. Turn the Perfect Airt Air Purifier power switch to on

position.

d. The power indicator light above the Air Purifier power

switch should illuminate (see Fig. 13).

e. Check to ensure the light goes off when the Perfect Airt

Air Purifier power switch is set to off, when the blower

goes off, or when the HVAC system power is turned off.

NOTE:

Upon power--up, the light will come on for

approximately 5 seconds and if no flow is detected, it will go off.

If no air purifier cartridge is detected, the flow sensor will detect

this and turn off after approximately 7 seconds.
Step 2

—Evolution Control
a. When the Perfect Airt Air Purifier is used with an Evolu-

tion Control, the Evolution Control can be configured to

remind the homeowner when it is time to change the Per-

fect Airt Air Purifier cartridge. This maintenance re-

minder can be based on either the TrueSenset dirty filter

algorithm or time. The installer should use their discretion

to select the most appropriate option based on the initial

system static pressure.

Step 3

—Maximizing Performance
a. Maximum air purification performance is obtained when

the furnace blower is set for continuous operation on the

thermostat or Evolution Control.

Door Switch Magnet

A06369

Fig. 12

--- Door Switch Magnet

Power Indicator

A06370

Fig. 13

--- Power Indicator

MAINTENANCE

The Perfect Airt Air Purifier is designed to require minimal

maintenance. Maintenance is limited to the replacement of the

air purification cartridge and inspection/brush cleaning of the

ionization array. Frequency of air purifier cartridge replacement

and cleaning of the ionization array may vary depending on

ductwork design and local environmental conditions.
To replace the air purifier cartridge, complete the following
steps:
Step 1

—Turn the heating and cooling system power off.

ELECTRICAL SHOCK AND HIGH VOLTAGE

HAZARD
Failure to follow this warning could result in personal injury

or death.
Before installing or servicing system, always turn off main

power to system. There may be more than one (1) disconnect

switch.

!

WARNING

Step 2

Turn the Perfect Airt Air Purifier switch to the off

position.
Step 3

Remove the Perfect Airt Air Purifier door.

Step 4

Slide out the old air purifier cartridge and discard.

Step 5

Install the new air purifier cartridge.

NOTE: Make sure that the arrows on the air purifier cartridge

point toward the fan coil. This should be in the same
direction as airflow.

Step 6

Replace the Perfect Airt Air Purifier door.

Step 7

Turn the Perfect Airt Air Purifier switch to the on

position.
Step 8

Turn heating and cooling system power on.