Machine actions

Causes

Solutions

The machine grinds the
coff ee beans but no coff ee
comes out.
(See note)

There is no water.

Fill the water tank and prime the
circuit (see "Using the Machine for
the First Time" chapter).

The brew group is dirty.

Clean the brew group (see "Weekly
Cleaning of the Brew Group" chap-
ter).

The circuit is not primed.

Prime the circuit (see "Using the
Machine for the First Time" chapter).

This might occur when the ma-
chine is automatically adjusting
the dose.

Brew a few cups of coff ee as
described in the “Saeco Adapting
System” chapter.

The dispensing spout is dirty.

Clean the dispensing spout.

The beverage is too weak.
(See note)

This might occur when the ma-
chine is automatically adjusting
the dose.

Brew a few cups of coff ee as
described in the “Saeco Adapting
System” chapter.

The beverage is brewed
slowly.
(See note)

The coff ee grind is too fi ne.

Change coff ee blend or adjust the
grind as explained in the “Adjusting
the Ceramic Coff ee Grinder” chapter.

The circuit is not primed.

Prime the circuit (see "Using the
Machine for the First Time" chapter).

The brew group is dirty.

Clean the brew group (see "Weekly
Cleaning of the Brew Group" chap-
ter).

Coff ee leaks out of the dis-
pensing spout.

The dispensing spout is clogged.

Clean the dispensing spout and its
holes.

The lower part of the dispensing
spout is not correctly positioned.

Position the lower part of the dis-
pensing spout correctly.

Note:

* These problems can be considered normal if the coff ee blend has been
changed or if the machine has just been installed. In this case wait until the
machine performs a self-adjusting operation as described in the "Saeco
Adapting System" chapter.