Bunn G9-2T HD User Manual

Page 16

Advertising
background image

1 6

SERVICE (cont.)

Snubber

Location:

The snubber is located at the back of the motor

attached to the right side of the wiring harness.

Removal and Replacement:
1.

Remove the snubber wires from the motor ter-
minals.

2.

Cut the ties holding the snubber to the wiring
harness.

3.

Refer to the following illustration when recon-
necting the wires.

4.

Fasten the snubber to the wiring harness using
new ties.

Solenoid(s)

Location:

The solenoids are located on the mounting plate

immediately beneath the hoppers.

Test Procedure:
1.

Unplug the grinder.

2.

Check the voltage across the left or right sole-
noid coil terminals with a voltmeter when the
Off/On/Start switch is momentarily pressed to
the “START” (lower) position and released (hop-
per selector switch must be corresponding to
the suspect solenoid). Plug-in the grinder. The
indication must be 120 volts ac.

3.

Unplug the grinder.

If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to

the

Wiring Diagram

and check the grinder wiring har-

ness.

4.

Separate the connectors on the white/brown
wires of the solenoids from the connectors on
the grinder wiring harness. (White/orange and
red/black to the left solenoid and white/yellow
and red/black to the right solenoid.)

5.

Check for continuity across the white/brown
wires on the suspect solenoid coil.