Controls – Bogen UTI312 User Manual

Page 13

Advertising
background image

13

Controls

Paging Level

The ZX3 module has controls for adjusting the audio level of each zone
independently.These serve as master level controls that allow for overall
zone control. Setting the initial volume to half is a good starting point. If
the speakers have their own level control, then the installer will have to
determine the proper setting for each speaker depending on the
application. Each level control includes an LED indicator above it to
indicate if the zone is active.

Music Level

The UTI3

12 has two background music input level controls. Once the

page level has been adjusted, set the music level control to the desired
background music level.

Tone Level

The Tone Level control sets the level for Tone Trigger

1 and 2,

pre-announce tone, confirmation tone, and code call tones.

Night Ring Level

The Night Ring Level control sets the level for the Night Ring tone.

Limiter Threshold

Because everyone doesn’t speak at the same level, the UTI3

12 includes a

limiter threshold control that prevents loud voices from booming out of
the paging system’s speakers. The limiter restricts the input signal to a
preset level regardless of the input level. To set the limiter, follow the
directions below.
1. Turn off the limiter by rotating the control fully counterclockwise.
2.

Hold the telephone handset in a normal position and speak in a
normal voice distinctly into the mouthpiece.

Adjust

the limiter control until the limiter active LED starts to
come on.

The ZX3 module level controls can be adjusted without disturbing the
limiter adjustment.

Advertising