A R C H I T E C T U R A L A N D E N G I N E E R I N G S P E C

S H I P P I N G S P E C S :

T E C H N I C A L S P E C S

Individual Bag Dim. (Approx.)

6.25"L x 1.50"W x 5.00"H

Weight

0.16 lbs.

Cube

0.03 ft3

UPC

0 29054 00057 6

Master Carton Dimensions

10.25"L x 4.75"W x 6.38"H

Master Pack

12

Weight

2.1 lbs.

Cube:

0.19 ft3

I2of5:

100 29054 00057 3

Pallet Information

Cases per Layer

35

Number of Layers:

6

Cases per Pallet:

210

Units per Pallet:

2,520

Cube:

54.7 ft3

Weight:

695 lbs.

Dimensions:

3.5 L x 1.5 H

Weight:

2.2 oz

Operating Voltage:

120V AC 60Hz

Operating Current:

.02 amps (standby/alarm)

Temperature Range:

40°F (4°C) to 100°F (38°C)

Humidity Range:

10% to 90% relative humidity (RH)

Interconnections:

Up to 18 units of First Alert or BRK Smoke, CO and

Heat Alarms. Maximum of 12 smoke alarms. See

user’s manual for details.

Listing:

Meets UL217, UL2034, UL539,ULC S-531,

CSA6.19 and ULCS-530 for accessories.

©2009 BRK Brands, Inc. a Jarden Corporation
Company (NYSE: JAH)

3901 Liberty Street Road
Aurora, IL 60504-8122
All rights reserved

First Alert is a registered trademark of the First Alert Trust
BRK is a registered trademark of BRK Brands, Inc.
CM2946

CAT.

RM4

BRK
Relay
Module

BRK
Alarm

Auxiliary

Device

Auxiliary Device
AC Power

Alarm
AC
Power

CONTACT RATINGS (MAXIMUM):

VOLTAGE

RESISTIVE

MOTOR

120V AC

15 AMP

1/3 H.P.

30V

DC 15 AMP

After installation, test the interaction of the auxiliary
device with the alarm by pressing the alarm test button.

This accessory relay is designed to activate auxiliary devices such as bells, lights
and door closers. The RM4 Relay is intended for use with BRK and First Alert
Smoke, Heat, and Carbon Monoxide Alarms.

To install this relay to an alarm, connect the power wires as listed below. See diagram
for connections. Note: If wiring the relay remote from the alarm, use a maximum of
1000 feet [300 meters] of #18AWG or larger wire rated at least 300V.

ALARM CONNECTION

RELAY

BLACK WIRE

(HOT)

BLACK WIRE

WHITE WIRE

(NEUTRAL)

WHITE WIRE

ORANGE WIRE

(INTERCONNECT)

ORANGE WIRE

Now connect the accessory to be activated by the relay to the relay’s switch contact
wires as listed below. (Use wiring appropriate to the auxiliary device being controlled.)
NOTE: Since voltage is present on all relay contact wires at some time during operation,
the installer must properly insulate any unused relay contact wire.

BROWN WIRE: HOT CONTACT TO AUXILIARY DEVICE
GRAY WIRE:

NORMALLY CLOSED CONTACT

BLUE WIRE:

NORMALLY OPEN CONTACT

BLUE

(N.O.)

GRAY

(N.C.)

WHITE

NEUTRAL

WHITE

ORANGE

BLACK

INTERCONNECT

UNSWITCHED 120V AC

60 Hz SOURCE

{

TO ADDITIONAL ALARMS

{

HOT

ORANGE BLACK

BROWN