Troubleshooting

problem

Solution

Dumbbell handle does not fully insert into base

when no plates are selected (handle has no

plates attached).

1. Make certain that both adjustment knobs are set directly to the num-

ber 5.

Dumbbell handle does not fully insert into base

when plates are selected (handle has plates

attached).

1. Check to see if you have selected different weights on each side of the

dumbbell (for example one adjustment knob is set to 2 and the other is

set to 3). If this is the case, you must replace the dumbbell in the base

with the same orientation in which it was was withdrawn. This is to

allow the plates to settle back into the correct and vacant openings in

the base.

2. Verify that the plates not selected (those plates remaining in the dumb-

bell base) are in their correct spots and have not been moved to differ-

ent support slots. This may be blocking the dumbbell from fitting back

into the base.

Adjustment knob will not turn while handle is in

base.

1. Check to assure that the dumbbell handle is fully depressed into the

dumbbell base. If not fully depressed, the locking mechanism will not

be released and may prevent the adjustment knobs from rotating.

2. Check to see if any weight plates have been put into the base assem-

bly backwards with the “Locking Tab” facing the grip of the dumbbell

handle. All weight plates must have the selection tongue facing away

from the grip of the dumbbell handle.

3. Check to see if there is any dirt, debris or other obstruction in the

dumbbell base. You may need to remove the weight plates from the

base to accomplish this check. Remember to put each weight plate

back in its appropriate location with the selection tongue facing away

from the dumbbell grip.

Plates are not secured to the handle and drop out.

1. Confirm that all of the weight plates have the “Locking Tab” facing

away from the dumbbell grip. If one or more of the weights are inserted

backwards with “Locking Tab” facing inward toward the grip, the

handle can get blocked, and the plates may wedge into the handle.

2. Verify that the plates not selected (those plates remaining in the dumb-

bell base) are in their correct spots and have not been moved to differ-

ent support slots. This may be blocking the dumbbell from fitting back

into the base.

Owner’s Manual