13. Technical Specifications

Qualified Output Power:

> 0 dBm < +4.0 dBm @ 25

o

C Receive sensitivity Single Slot = -83 dBm with

0.1% BER

13.1. Storage and Operating Environment

13.1.1. Storage

Temperature: -10

o

C to +60

o

C

Humidity: 8% to 95% non-condensing

13.1.2. Operational

Temperature :

0

o

C to +40

o

C

Humidity

: 20% to 75% non-condensing

13.2. Power requirements

13.2.1. Input Voltage Requirements

The product was qualified using a fully rectified AC/DC power supply supplying 550mA @ 5V. To ensure your
product performs within the regulatory requirements, it is recommended that you use the AC/DC adapter supplied..
For your information only, the voltage range is given below. Minimum 5.0 V – Maximum 13.6 VDC NOTE: Power
supplied through Pin 9 of the RS 232 connector does go through the regulator and has the same input requirements
as the DC jack, +5.0 to 13.6 VDC.